Submersible Borehole Pumps: How to Select a Deep Well Pump for Wells and Farms
How to size a deep well submersible pump from the pump test: pumping level and drawdown, total head, setting depth, check valves, cable voltage drop, protection, solar pumping and an RFQ checklist.
Choose a submersible borehole pump from the well, not the catalogue: find the flow the well can sustain and its pumping water level from a pump test, add the lift to the surface, pipe friction and the pressure you need at the outlet to get total head, then pick a pump that fits the casing and a motor, cable and check valves that suit the setting depth. The submersible pump suppliers in the UAE listed on ListGCC can quote once you have those figures.
This guide is for farm owners, well contractors, compound managers and procurement teams buying deep well pumps. Our main guide to water pumps in the UAE and Saudi Arabia already covers motor cooling flow and flow sleeves, start limits, saline water materials and the Saudi groundwater licence; here we go further into the well itself: yield and drawdown, head, setting depth, check valves, drop cable, protection and solar drives.
Start with the well: yield, static level and pumping level
Three numbers describe a well for pump selection. The static level is the water level when nothing is being pumped. The pumping level is the level while the well is pumped. Drawdown is the difference: the fall in water level caused by pumping. Specific capacity, the well yield per metre of drawdown, tells you how hard the well can be pushed.
These come from an aquifer test (pumping test), in which the well is pumped at a controlled rate while the water level is measured. Ask the drilling contractor for the test record: pumping rate, static level, pumping level at each rate and how long the level took to stabilise. Without it, any pump size is a guess.
Size the flow to the well, not the pump. A pump that delivers more than the well yields drags the water down to its intake and runs dry or draws sand.
Size it to the licence too. In Saudi Arabia the groundwater use permit fixes how much you may abstract; the main guide explains the MEWA licence. Pump to the lower of well yield and licensed quantity.
Allow for decline. If the aquifer level falls over the years, the pumping level falls with it, so check that the pump curve still delivers useful flow with a deeper pumping level.
How do you calculate total dynamic head for a borehole pump?
Total dynamic head (TDH) is the sum of four parts at the design flow:
Lift from the pumping level (not the static level) to the wellhead.
Elevation from the wellhead to the point of delivery, such as the top inlet of a tank or the highest emitter.
Friction in the rising main, wellhead fittings, check valves, meter and the pipe to the delivery point.
Pressure required at the outlet: zero for a free discharge into an open tank, or the working pressure of a drip or sprinkler system, converted at roughly 10 m per bar.
Worked example
These are illustrative assumptions to show the arithmetic. A farm well has a pumping level of 80 m at the required flow. Water goes to a ground tank whose inlet is 5 m above the wellhead, and the rising main and surface pipe lose 6 m at that flow. TDH = 80 + 5 + 6 = 91 m. If the same pump fed a drip system needing 1.5 bar instead of the tank, TDH would rise to about 106 m. That 15 m difference can mean several more stages, and it is the reason many farms pump to a tank and boost from there; our guide to booster pump sizing covers the second stage.
A borehole set is a pump end (the stack of impellers and diffusers) coupled to a submersible motor below it. The outside diameter must pass down the casing with clearance for the drop cable and its guard. Makers name ranges by nominal well size: Pedrollo, for example, lists 3-inch, 4-inch and 6-inch borehole pumps, some in precision-cast stainless steel, and Franklin Electric lists 4-inch, 6-inch and 8-inch submersible motors. Check three things when a supplier pairs a pump end from one maker with a motor from another:
The motor's power covers the pump's maximum power across the whole curve, not just at the duty point.
The coupling and mounting dimensions match the motor standard the pump end is built for.
The motor maker's thrust rating covers the pump's down thrust. Franklin's manual warns that a pump running with too little head creates upthrust, acceptable briefly at each start but damaging to the motor's upthrust bearing if continuous.
Where should the pump be set in the well?
Below the lowest expected pumping level, with margin for seasonal decline, so the intake never breaks suction.
Clear of the bottom. Franklin's installation checklist says the pump should be at least 3 m (10 ft) from the bottom of the well to allow for sediment build-up.
Not in or below the screens without a flow sleeve. Franklin lists a pump set in or below screens or perforations as one of the cases that needs a flow inducer sleeve; the cooling rules are in the main guide.
No drawdown seals. Franklin does not recommend seals that close the well around the pump above its intake, because the suction created can drop the pressure around the motor below atmospheric, and allowable motor temperature assumes atmospheric pressure or higher.
Check valves: how many and where?
Franklin Electric recommends that one or more check valves always be used in submersible installations. Its rules, from the 50 Hz application, installation and maintenance manual:
If the pump has no built-in check valve, fit a line check valve in the discharge within 7.6 m (25 ft) of the pump and below the drawdown level. For deeper settings, follow the pump maker's spacing; more than one may be needed, but not more than recommended.
Swing check valves are not acceptable: they close too slowly and cause water hammer. Use the pump's internal valve or spring-loaded valves.
Use only positive-sealing valves. Drilled or drain-back valves may prevent backspin but create upthrust and water hammer.
The manual explains what goes wrong without them. With no valve, water in the riser flows back and spins the pump backwards, and starting during backspin can break shafts and impellers. With a leaking or drilled valve, every start is at zero head, causing upthrust. If the lowest valve sits more than 9.1 m (30 ft) above the static water level, or a lower valve leaks while the one above holds, a vacuum forms in the riser and the next start produces a hydraulic shock that can split pipes and damage the pump and motor.
Drop cable for long settings
Deep settings put a long cable between the panel and the motor, and voltage drop in that cable is a common reason for overheating and nuisance trips. Franklin's 50 Hz cable tables are built to keep motor voltage at no less than 95 percent of supply voltage at maximum rated running current, while keeping starting voltage and cable temperature acceptable. Points from the manual worth putting in a specification:
Cable must be suitable for submerged operation. The metric tables use copper conductors with 70 °C insulation and give maximum lengths per conductor size for each motor rating; larger cable is needed where local codes or higher temperatures require it.
For three-phase motors, the cable from the service entrance to the controller should not exceed 25 percent of the table's maximum length.
Two cable sizes can be combined. The manual's example: a 2.2 kW, 230 V single-phase motor allows 60 m of 4 mm² cable; an existing 40 m run of 4 mm² uses 40 ÷ 60 = 66.6 percent of the allowable drop, and the remaining 50 m down the well must use a size whose fraction keeps the total at or below 100 percent.
Strap the cable to the riser every 3 m with padding, so it does not sag or chafe.
Ask the supplier to state the cable size and length used in their selection, and the voltage they assumed at the panel. If the supply at the panel runs below nominal voltage at peak times, that margin shrinks, so measure it.
Protection, testing and installation details
Insulation resistance. Franklin's checklist calls for a 500 or 1,000 V DC megohmmeter test from each lead to the motor frame before installation, at least 200 megohms for a new motor without drop cable, and repeated checks as the set is lowered; a sudden drop points to cable, splice or lead damage.
Surge protection. Franklin calls for properly rated surge arresters on all submersible installations, grounded metal to metal down to the lowest drawdown water level; grounding the arrester only to the supply ground or a driven rod provides little or no protection.
Torque. Starting torque tries to unscrew right-hand threaded joints. Franklin recommends tightening all threaded joints to at least 13.57 N·m per motor horsepower, and notes that high-power pumps at shallow settings may need joints tack or strap welded.
Starting method. Franklin gives daily start limits by motor size and notes that with a properly configured reduced voltage starter or variable frequency drive, its 7.5 to 30 hp three-phase motors can be started up to 200 times in 24 hours. With a generator, size it from the generator maker's recommendations and the motor's locked rotor current.
Start limits, voltage at the motor, surge arresters
Grid with variable frequency drive
Direct supply to irrigation or a pressure system with changing demand
Motor maker's drive rules and filters, minimum speed for cooling flow and thrust
Diesel generator
Remote wells without grid
Generator sized on locked rotor current; voltage swings when the load changes
Solar (PV array, controller, pump)
Remote farms and livestock wells pumping into storage
Seasonal output, storage tank volume, array sized to the pump
Solar borehole pumping
A solar pump system has three main parts: one or more PV panels, a controller and the pump. The controller matches the pump's power to what the panels deliver and switches off outside the pump's voltage range. DC motors suit small to medium systems up to about 4 kW; AC pumps need an inverter. Output varies with sunlight and season, so the usual design stores water in a tank rather than storing energy in batteries, which avoids an extra conversion step. Pedrollo's catalogue includes a 4-inch solar submersible series (FLUID SOLAR), and Franklin Electric runs a separate solar product site. Size the array from the pump, the daily water need and local sunlight, and size the tank to carry the farm through the hours or days the array cannot.
Sand and water quality
New wells should be developed until the water runs clear before the permanent pump goes in. Ask the supplier for the maximum sand content the pump is rated for and the material of the impellers and diffusers: Pedrollo's filters list brass, stainless steel and precision-cast stainless impellers across its ranges. For brackish groundwater, the main guide covers corrosion-resistant options; send a full water analysis with the RFQ.
Before drilling or deepening a well, confirm with the competent authority in your emirate whether a permit is required and what abstraction it allows. Surface motors and controls fall under the UAE motor efficiency rules described in the main guide; IEC 60034-30-1 itself excludes submersible motors.
Borehole pump brands to shortlist
Franklin Electric
Franklin Electric makes 4, 6 and 8-inch submersible motors, well pumps and controls, and publishes the detailed 50 Hz application and installation manual quoted throughout this guide. Its motors are often paired with other makers' pump ends.
Pedrollo
Pedrollo lists 3, 4 and 6-inch borehole pumps (4HR and 6HR in precision-cast stainless steel, 6ST in stainless steel), borehole motors and a 4-inch solar submersible range.
Borehole pump RFQ checklist
Pump test record: rate, static level, pumping level and stabilisation time; licensed abstraction in Saudi Arabia.
Casing internal diameter, well depth, screen positions and proposed setting depth.
Required flow and TDH, with the calculation: pumping level, elevation, friction, outlet pressure.
Water analysis: temperature, TDS, chlorides, pH and sand content.
Power: grid voltage and phase, generator or solar, and cable length from panel to motor.
Pump end and motor makes, motor rating, thrust rating and starter or drive type.
Cable size, check valve type and spacing, surge arrester and flow sleeve if needed.
Materials of impellers, diffusers, shaft and casing; curve at the duty point; test certificate.
How do I choose the right size submersible pump for my well?
Get the pump test first: the flow the well sustains and the pumping level at that flow. Choose a design flow no higher than the well yield or the licensed abstraction. Add the lift from the pumping level, the elevation to the delivery point, pipe friction and any outlet pressure to get total head. Pick a pump whose curve passes that flow and head near its best efficiency, in a diameter that fits the casing.
What is the difference between static water level and pumping water level?
The static level is the water level in the well when nothing is pumped. The pumping level is the level while the pump runs, and it is always lower. The difference is the drawdown. Pump head must be calculated from the pumping level, otherwise the pump will deliver less water than expected once the level falls.
How deep should a borehole pump be installed?
Below the lowest expected pumping level with a margin for seasonal decline, and at least 3 m above the bottom of the well to allow for sediment, as Franklin Electric's installation checklist states. If the pump sits in or below the screens, fit a flow inducer sleeve so the motor still gets cooling flow.
Do submersible pumps need a check valve?
Yes. Franklin Electric recommends one or more check valves in every installation, with the first within 7.6 m of the pump if the pump has none built in. Use spring-loaded or internal valves, never swing check valves, and never drilled valves. Missing or leaking valves cause backspin, upthrust and water hammer.
What size cable does a deep well pump need?
It depends on motor rating, voltage and cable length. Franklin Electric's tables keep motor voltage at 95 percent or more of supply voltage at full running current and give a maximum length for each copper conductor size. Long settings often need a larger size than the motor leads; two sizes can be combined if their fractions of allowable length add up to no more than 100 percent.
Can a solar pump replace a diesel pump on a farm well?
Often, for wells pumping into storage. A solar system has panels, a controller and a pump, and output follows the sun and the season, so the design stores water in a tank rather than energy in batteries. DC solar motors suit systems up to about 4 kW; larger duties use AC pumps with an inverter. Size the array to the pump and the daily water need.