Anti-slip tiles are rated mainly in two ways: an R rating from R9 to R13 from the German DIN 51130 ramp test (higher is less slippery), and a pendulum test value (PTV), where 36 or more means low slip potential. Choose the rating by what will be on the floor (water, soap, oil), what people wear (shoes or bare feet) and the slope, then ask ceramic and porcelain tile suppliers in the UAE or in Saudi Arabia for the test report on the exact series and finish.
This spoke is for consultants, facility managers, hotel and mall operators, pool contractors and buyers who need to specify or check slip resistance. It explains what each test measures, the R and A, B, C classes, the pendulum values, why the HSE has reservations about ramp ratings, and how to set requirements by zone. Tile groups, abrasion classes and the Saudi and Dubai tile rules are in our main guide to ceramic and porcelain tiles in the UAE and Saudi Arabia. ListGCC did not test any tiles; everything below comes from the UK Health and Safety Executive, the EU-OSHA OSHwiki, the German Social Accident Insurance (DGUV) and the makers' own pages.
The ramp test and R ratings (DIN 51130)
The short answer: R ratings come from a person walking on an oiled, tilting ramp in safety boots, and the angle at which they start to slip sets the class.
DGUV's Institute for Occupational Safety and Health describes the method: a test person walks forwards and backwards, upright, on the floor covering, with engine oil applied and safety footwear with a defined outsole; the ramp is tilted until the person begins to lose footing, and that angle measures the slip resistance. Floor coverings fall into five classes, R9 to R13: R9 meets the lowest requirement, R13 the highest. The HSE's information sheet gives the angle bands:
Class (DIN 51130)
Slip angle (degrees)
HSE comment
R9
6 to 10
Slippery when used in wet or greasy conditions
R10
10 to 19
In some instances slippery when wet or greasy; covers a coefficient of friction from 0.18 to 0.34
R11
19 to 27
R12
27 to 35
R13
Over 35
Least slippery class
The standard itself has been revised: DIN Media lists DIN 51130:2010-10 as withdrawn and replaced by DIN 51130:2014-02, so ask for test reports to the current edition.
Barefoot ratings A, B and C (DIN 51097)
For pool surrounds, showers and changing rooms, the relevant ramp test is DIN 51097, carried out barefoot with soapy water. The HSE lists the bands as A (12 to 17 degrees), B (18 to 23 degrees) and C (over 24 degrees), and warns that floors rated A, and in many instances B, "will be slippery when wet". For barefoot wet areas, that points to C, confirmed by a pendulum test with the barefoot slider described below.
The pendulum swings an imitation heel, a standard rubber slider, across the floor, and the slipperiness of the surface shows directly in the pendulum test value. It is covered by BS 7976 Parts 1 to 3, and the HSE has adopted it as its standard method for assessing floor slipperiness in dry and contaminated conditions. The HSE interprets results as follows:
Pendulum test value (PTV)
Slip potential
0 to 24
High
25 to 35
Moderate
36 and above
Low
Slider rubber matters: Slider 96 gives enough information for shod pedestrians; for barefoot areas use Slider 55; on profiled floors both may help.
Test wet: the pendulum can be run on dry and water-contaminated surfaces. Ask for the wet result, because that is the condition in which people slip.
Lab and site: the HSE describes its pendulum and roughness method as suited both to laboratory assessment and to installed floors, so the same measure can be used at tender and at handover. OSHwiki notes that the ramp test is not suitable for on-site tests.
Operator: the HSE says the pendulum must be operated and interpreted by a trained, competent person, and profiled floors may need tests in several directions.
Surface roughness as a quick check
The HSE also uses surface microroughness (Rz, the mean of several peak-to-valley measurements) to predict slipperiness in water-wet conditions:
Rz roughness
Slip potential (water-wet)
Below 10 µm
High
10 to 20 µm
Moderate
20 µm and above
Low
Those figures apply to water. The HSE notes that thicker contaminants such as oils need more roughness to keep the same slip resistance, so floors that see oil or fat, such as kitchens and workshops, need more roughness than floors that only get wet. Hand-held roughness meters are quick, but they are unsuitable on carpet and on undulating or very rough floors.
Why the HSE is cautious about ramp ratings
R ratings are the figure most tile datasheets carry, so it helps to know their limits. The HSE has "reservations" about DIN 51130 and DIN 51097 because neither uses contaminants representative of most workplaces (motor oil with cleated safety boots, soap with bare feet), and because the way results are reported and applied "is a cause for concern", sometimes leading to the wrong floor being installed. A single class such as R10 spans a wide range of friction. OSHwiki adds that no single test is perfect, and that some tribometers give over-optimistic readings on wet, polished or glazed surfaces.
The practical answer is to use both: an R or A, B, C class to shortlist tiles, and a wet pendulum value, with the right slider, to confirm the finish you are buying and the floor once installed.
Rules in the UAE and Saudi Arabia
ListGCC did not find a UAE or Saudi regulation that assigns R classes or PTV values to building areas in the way German workplace rules do. In practice the requirement is set by the project: the consultant's specification, the client's or operator's design standards, and the authority's approvals. In Saudi Arabia, the tiles themselves must still meet SASO's building materials regulation, Part 4, including the Saudi Quality Mark for ceramic tiles; in Dubai, Dubai Municipality's laboratory certifies ceramic tiles to ISO 13006:2018. Neither scheme sets a slip class for you, so write it into the specification zone by zone.
Setting slip requirements by zone
Use the HSE's interpretation as the backbone: a wet PTV of 36 or more for low slip potential, with Slider 96 for shod areas and Slider 55 for barefoot areas, and R or A, B, C classes to shortlist tiles. The table is a framework for the specification; confirm values with the consultant and the operator's standards.
Zone
Contaminant and footwear
What to ask for
Dry offices, bedrooms, living areas
Occasional spills, shod or socks
Dry and wet PTV for the finish; avoid relying on a polished finish where spills are likely
Entrances, lobbies, mall concourses
Water and sand from outside, shod
Wet PTV 36 or more (Slider 96); above R10 on the ramp scale; entrance matting
Bathrooms and toilets
Water and soap, shod
Wet PTV 36 or more; above R10
Showers, changing rooms, pool surrounds
Water and soap, barefoot
DIN 51097 class C; wet PTV 36 or more with Slider 55
Commercial kitchens, food production
Water, fat and oil, shod
A high R class with the maker's test report; roughness and wet PTV checked with the kitchen's actual contaminants in mind
Workshops, car washes, loading areas
Oil, water, detergents, shod
A high R class; profiled surfaces; pendulum tested in several directions
Ramps, slopes and external stairs
Rain, irrigation, sand, shod
A higher class than the flat floor next to it; wet PTV on the finished surface
Sand and dust: treat entrances where sand is tracked in from outside as contaminated floors: plan matting and choose a finish whose wet PTV has been checked.
Irrigation and wash-down: podium terraces, villa courtyards and car park ramps are wetted by irrigation and cleaning as well as by rain; specify them as wet areas.
Pools in hotels and compounds: barefoot users and pool water make pool decks the zone where the barefoot class and Slider 55 result matter most. See the spoke on mosaic tiles for pools and bathrooms for the installation system.
Cleaning: cleaning products and any sealer applied after laying become part of the walking surface. Ask the tile maker which products keep the rating, and re-test with the pendulum during operation.
Makers and test reports
Slip data belongs to a specific series and finish. RAK Ceramics lists a Super Utility Tiles (SUT) range among its tile categories, and Saudi Ceramics lists outdoor tiles among its products. Whichever maker you use, ask for:
The test report, with the standard and edition (for example DIN 51130:2014), the lab and the date.
R class and, for barefoot zones, the DIN 51097 class.
Wet PTV with Slider 96 and, for barefoot zones, Slider 55.
Confirmation that the report covers the exact finish (matt, structured, polished) and size you are buying.
Cleaning and maintenance instructions that keep the rating.
R10 is a slip resistance class from the German ramp test DIN 51130, in which a person in safety boots walks on an oiled, tilting ramp. R10 means slipping began at a ramp angle between 10 and 19 degrees. The UK HSE warns that R9, and in some instances R10, floors will be slippery in wet or greasy conditions, so for wet areas ask for a higher class and a wet pendulum value.
Which R rating is best for bathrooms?
There is no single legal value in the UAE or Saudi Arabia; the project specification sets it. Because the HSE says R9 and some R10 floors are slippery when wet, specify bathroom floors above R10, with a wet pendulum value of 36 or more. For showers and barefoot areas, ask for DIN 51097 class C and a pendulum result with the barefoot Slider 55.
What is a good pendulum test value?
The HSE classes a PTV of 36 or more as low slip potential, 25 to 35 as moderate and 24 or less as high. Ask for the wet value, tested with Slider 96 for shod areas and Slider 55 for barefoot areas, on the exact finish. The pendulum can also be used on the installed floor, so the same figure can be checked at handover.
What is the difference between R ratings and A, B, C ratings?
Both come from German ramp tests. R9 to R13 (DIN 51130) are measured with safety boots and motor oil, for workplaces and shod areas. A, B and C (DIN 51097) are measured barefoot with soapy water, for pools, showers and changing rooms. The HSE says A, and in many instances B, floors will be slippery when wet, so C is the class to ask for in barefoot wet areas.
Are anti-slip tiles harder to clean?
They need the cleaning method their maker specifies, which may differ from the routine for smooth tiles. Ask the tile maker for its cleaning instructions and which products keep the slip rating, since cleaning products and sealers become part of the walking surface. Re-test with a pendulum during operation if the floor seems to have become slippery.
Do UAE or Saudi rules set slip ratings for floors?
ListGCC did not find a UAE or Saudi regulation that assigns slip classes to building areas. The requirement comes from the consultant's specification, the client's or operator's design standards and the authority's approvals. Tiles sold in Saudi Arabia must still meet SASO's building materials regulation, but that does not set a slip class, so write one into the specification for each zone.
How tile sizes work on site: nominal, work and coordinating sizes under ISO 13006, rectified edges, thickness and weight, lippage, substrate flatness and what large-format slabs need.
How to read tile adhesive and grout codes: EN 12004 and EN 13888-1 classes, which to specify for porcelain, large tiles, pools and outdoors, when epoxy grout is worth it and movement joints in heat.
Porcelain and ceramic tiles compared for UAE and Saudi projects: the 0.5% absorption definition, strength and abrasion, outdoor use, adhesives, cutting, cost drivers and which body suits each area.