Radar level transmitters measure the level of liquids and solids by timing microwave pulses, with no contact with the product and little effect from density or temperature. In the UAE they gauge crude and product tanks, process vessels, water storage and silos. This page explains non-contact and guided wave types, frequency, TDRA and ECAS-Ex approvals as of 2026, brands and what drives price.
0 suppliers found
Skip the search. Post your requirement and we'll connect you with verified radar level transmitters suppliers who quote for your order directly.
Tell us about radar level transmitters in UAE and receive competitive quotes from verified suppliers — free, fast, and no obligation.
A radar level transmitter sends microwave pulses towards the product surface and works out the level from the time the echo takes to return. It is the main continuous option within level measurement instruments in the UAE, used on crude and product storage at Fujairah and Ruwais, process vessels and separators, desalination and water tanks, and cement and sand silos. Endress+Hauser explains that its Micropilot works with high-frequency radar pulses emitted by an antenna, and the level is calculated from the known tank geometry.
| Type | Typical UAE use | Key specification points |
|---|---|---|
| Non-contact pulse radar | Storage tanks, water and chemical tanks, simple vessels | Frequency band, antenna type, range, accuracy, process temperature and pressure |
| Non-contact FMCW radar | Agitated, corrosive or tall vessels and silos | Narrow beam, antenna size, obstruction handling, accuracy class |
| Guided wave radar (TDR) | Vessels with foam, nozzles, or low-dielectric liquids, and interface measurement | Probe type and length, process connection, dielectric constant, build-up |
| High-pressure and high-temperature radar | Boiler drums, hot oil, gas plant vessels | Process seal, pressure and temperature rating, SIL capability |
| Hygienic radar | Food, beverage and pharma tanks | Hygienic fittings, cleanability, wetted materials |
KROHNE lists FMCW radar in its OPTIWAVE range, including a model for agitated and corrosive liquids and another for solids, and guided radar in its OPTIFLEX range, including one for liquids at high temperature and pressure. Endress+Hauser lists models up to 80 m and 125 m range, and the non-contact principle is described as maintenance-free and unaffected by medium density and conductivity.
Choose a higher frequency for a narrower beam when the vessel has internal obstructions or a small nozzle, and a lower frequency when foam, condensate or dust attenuate the signal. VEGA makes radar in three bands, 80 GHz, 26 GHz and 6 GHz, and states that its VEGAPULS 6X combines the benefits of all three in one instrument. Endress+Hauser identifies its FMR60B, FMR62B, FMR63B, FMR66B and FMR67B as 80 GHz models.
Radar tolerates hot air and vapour better than ultrasonic level sensors, which suit shaded wet wells. For small tanks and sticky products consider capacitance level probes, and for pump control or independent alarms use float level switches. A hydrostatic pressure transmitter is a common back-up for water.
A usable radar quote states the product and its dielectric constant, tank height, nozzle size and length, internals, operating temperature and pressure, and the accuracy class expected. Without these, a supplier can only guess the antenna and frequency. Add whether the tank has a stilling well, a floating roof or a fixed roof with a gauge hatch, because each changes the mounting and the echo.
Ask for the wetted materials in writing, the process seal details for pressure duty, and the ingress rating of the housing. On UAE hydrocarbon tanks, add the hazardous-area marking you need, and on custody tanks add the verification method, for example comparison with a manual dip. Agree how the commissioning report and the empty and full calibration will be recorded, so that a replacement transmitter can be set up the same way later.
Radar copes with UAE conditions better than most principles because it is not affected by the temperature of the air above the product, though the electronics and antenna still need protection. Sun on a tank roof can push the transmitter head beyond its ambient limit, so shade it or use a remote display. Night-time condensation on antennas along the coast can build up, so ask about drip-off or purge options, and use stainless steel or coated housings near the sea. Dust in cement and sand silos needs an antenna rated for it.
As of 2026, a radar level transmitter in the UAE needs TDRA registration because it carries an intentional radio transmitter, ECAS-Ex certification for hazardous areas, and compliance with the tank owner's gauging specification. Confirm each point with the authority and the terminal operator.
| Requirement | Applies to | Authority |
|---|---|---|
| TDRA type approval and registration | All radar models with a radio transmitter | TDRA |
| ECAS-Ex certificate of conformity | Transmitters on hydrocarbon tanks and process vessels | MoIAT, through notified bodies |
| API MPMS Chapter 3.1B on automatic tank gauging | Inventory and custody transfer gauging on atmospheric tanks | API, called up by terminal owners |
| API Standard 2350 on overfill prevention | Independent high-level alarms on petroleum tanks | API, tank owner |
| Vendor approval | Instruments for ADNOC group facilities | ADNOC and operating companies |
TUV Rheinland states that telecom apparatus with an intentional radio transmitter must be registered with the TDRA before it can be used, sold or distributed in the UAE, with equipment registration valid for three years. Our ECAS and EQM guide shows how to verify a certificate, and the storage tanks and terminals page covers the wider terminal picture.
Radar transmitters are sold by manufacturers' regional offices, authorised distributors and tank gauging integrators. Endress+Hauser makes the Micropilot range, VEGA makes the VEGAPULS range and KROHNE makes OPTIWAVE and OPTIFLEX radar. Ask each bidder:
Our sourcing guide covers authorisation checks, and you can post your requirement for quotes.
Price follows range, antenna type, materials, accuracy class, pressure and temperature rating, SIL capability and hazardous-area approvals. Compact plastic-antenna units for water tanks are often in distributor stock, while high-pressure, flanged or custody-grade units are configured to order. Allow time for shipping to Jebel Ali, registration documents and commissioning, and ask for a quote that separates the transmitter from mounting hardware and a display.