Medium voltage switchgear in Saudi Arabia is the switching and protection equipment between 1 kV and 52 kV, typically at 13.8 kV on SEC distribution networks, supplied as air insulated lineups, gas insulated switchgear or ring main units. This page lists Saudi suppliers and covers 60 Hz ratings, IEC 62271-200 service continuity and internal arc classes, desert and coastal conditions, SF6 trends, and SEC and owner approvals.
0 suppliers found
Skip the search. Post your requirement and we'll connect you with verified medium voltage switchgear suppliers who quote for your order directly.
Tell us about medium voltage switchgear in Saudi Arabia and receive competitive quotes from verified suppliers — free, fast, and no obligation.
Medium voltage switchgear in Saudi Arabia is the metal-enclosed equipment that switches and protects MV circuits with vacuum or SF6 breakers, load break switches, fuses and earthing switches, controlled by protection relays. It belongs to the Saudi switchgear and panels family, and it is where a plant or building meets the Saudi Electricity Company (SEC) network or a private utility system.
A common Saudi distribution voltage is 13.8 kV. SEC's Al Aseelh substation in Jizan, for example, is listed by Power Technology at 380/132/13.8 kV, stepping power down to 13.8 kV for distribution. Industrial plants and some networks also run at 33 kV or other voltages, so the system voltage must be confirmed for each project.
| Equipment | Saudi application | What to specify |
|---|---|---|
| Withdrawable air insulated switchgear | Plant substations in Jubail, Yanbu and Ras Al Khair, water transmission and pumping | Rated voltage and 60 Hz frequency, short-time current, LSC2B, PM partitions, IAC class, owner relay standard |
| Gas insulated switchgear | Compact substations in cities, sandy or coastal sites, data centres | Insulating medium, tank design, cable plug system, gas monitoring |
| Ring main units | SEC secondary distribution, package substations feeding 400 V networks | SEC accepted model, switch and breaker ways, remote control for distribution automation |
| Metered MV intakes | Large customers taking supply at MV from SEC | SEC metering arrangement and approved layout |
MV switchgear feeds 13.8 kV distribution transformers, which in turn feed LV switchboards and PCCs. Large pumps and compressors may be started from MV motor control centres.
A Saudi MV switchgear tender should specify three IEC 62271-200 classifications: loss of service continuity (LSC), partition class (PM or PI) and internal arc classification (IAC). Together they say how safe the switchgear is to maintain and how much of the plant keeps running while you do.
The Saudi grid operates at 60 Hz, and the GCC Interconnection Authority links it to the 50 Hz GCC grid through a back-to-back converter. Rated frequency must appear on breakers, CTs, VTs and protection relays, and relay settings and IEC 61850 communication should follow the owner's standard.
Desert heat and dust favour sealed designs, coastal humidity favours good condensation control, and European SF6 rules are changing what makers offer. Each point should be written into the specification.
Outdoor package substations at inland solar plants, mines and new cities sit in direct sun and blowing sand. Ask for derated current at the real ambient, sun shields, filtered or sealed ventilation, and gas insulated or fully sealed designs where sand ingress is a risk. On the Gulf and Red Sea coasts, thermostatic heaters and sealed cable entries limit condensation and surface tracking.
ESB Networks summarises Regulation (EU) 2024/573 as banning the putting into operation of switchgear that relies on fluorinated gases from 1 January 2026 up to 24 kV and from 1 January 2030 above 24 kV up to 52 kV, within the EU. Saudi Arabia is not bound by this rule as of 2026, but European factories are redesigning ranges around vacuum and alternative gases. Ask bidders whether the offered GIS or RMU has an SF6-free equivalent, how gas is monitored and recovered, and how long spares will be supported.
As of 2026, MV switchgear in Saudi Arabia is accepted through IEC 62271 type tests plus SEC acceptance for network equipment and owner vendor approval for industrial plants. SEC publishes its own distribution material specifications, so ask SEC or the consultant for the current revision.
| Gate | Applies to | Authority |
|---|---|---|
| IEC 62271-200 and IEC 62271-100 type tests | All metal-enclosed MV switchgear and its circuit breakers | Accredited test laboratory certificates |
| Distribution material specification and model acceptance | RMUs and switchgear on or connected to the SEC network | Saudi Electricity Company |
| Vendor and material approval | Oil, gas, petrochemical, mining and water plants | Saudi Aramco, SABIC, Ma'aden, water utilities |
| Import conformity | Regulated components and accessories | SASO via SABER |
| Witnessed factory acceptance test | Each lineup | Owner or consultant inspector |
Read the SASO and SABER guide for industrial equipment before shipping switchgear or spare parts into the Kingdom.
Saudi MV switchgear comes from global makers with Saudi factories, offices or partners, and from secondary distribution specialists, with the owner's approved list deciding who can bid.
Coordinate the order with the MV power cables and terminations, the substation or e-house and the voltage transformers for metering and protection.
Panel count, fault rating, insulation type and owner requirements set the price; factory capacity, drawing approval and testing set delivery.
Locally produced RMUs generally reach site faster than custom primary lineups built abroad. To receive comparable offers, post your MV switchgear requirement with voltage, fault level, LSC and IAC classes and the approvals your owner needs.
A buyer's guide to transformers in the UAE and Saudi Arabia: types, data sheet ratings, IEC 60076, DEWA and SEC specifications, losses, Gulf heat derating, makers and what to put in an RFQ.
How to select a current transformer: ratio, metering and protection accuracy classes, burden, knee point, core balance CTs for earth fault, construction types and SEC requirements.
Where LV ends and MV begins, how GIS and AIS differ in size, cost and maintenance, what SF6 rules mean for Gulf buyers, how ring main units work and how to read an MV datasheet.