Fire rated glazing in the UAE is glass and its framing system tested to hold back fire for a set time, used in stair cores, corridor screens, lobbies, doors and facades. This page lists UAE suppliers and explains the glass types and E, EW and EI classes, the civil defence and Dubai ESL approvals, how heat and sun on UAE elevations limit some products, and what drives price and lead time.
0 suppliers found
Skip the search. Post your requirement and we'll connect you with verified fire rated glazing suppliers who quote for your order directly.
Tell us about fire rated glazing in UAE and receive competitive quotes from verified suppliers — free, fast, and no obligation.
Fire rated glazing is a glass and frame assembly that has passed a fire resistance test for a stated time and class, so it can sit in a fire-separating wall, door or facade. It is the passive, see-through part of the fire protection scope for UAE buildings, and in a UAE tower it often meets the fire rated doors and doorsets in the same stair core or lobby.
The glass on its own has no rating. The classification belongs to the tested combination of glass, frame, gaskets, fixings and the wall around it, so buy the system, not the panes. The main glass families are below.
| Glass type | Typical class | Where UAE projects use it |
|---|---|---|
| Special toughened (tempered) fire glass, for example Vetrotech PYROSWISS | E (integrity only) | Glazed doors and screens where heat transfer is acceptable, smoke screens, lift lobbies in some layouts |
| Coated toughened glass that reflects radiant heat, for example VETROFLAM or coated Pyropane | EW | Facade zones and windows near escape routes |
| Laminated glass with intumescent interlayers, for example AGC Pyrobel and Pyrobelite or Vetrotech CONTRAFLAM | EW or EI, from 15 up to 120 minutes and more | Stair cores, corridor screens, atria, fire compartment walls |
| Gel-filled or multi-chamber glass in large sizes, for example AGC Pyrobel-T | EW up to 120 minutes, EI up to 60 minutes | Tall feature screens, mall and hotel lobbies |
| Fire-rated framing in steel, aluminium or timber | Matches the glass test | Every assembly above; aluminium systems for facades and screens |
Under EN 13501-2, E means integrity: no flames or hot gases pass. EW adds a limit on radiant heat (AGC states 15 kW/m² for the class). EI adds insulation, so the protected face stays cool enough that people can pass close to it. The number after the letters is minutes, so EI 60 means integrity and insulation for 60 minutes. On US-based specifications the evidence comes from tests such as ASTM E119, UL 263, NFPA 257 and UL 9, which AGC lists alongside the European standards for its range.
Heat is the real Gulf limit for fire glass. Intumescent and gel interlayers are designed to react at high temperature, so their makers set a maximum service temperature, and a sun-facing elevation in a UAE summer can push glass close to it.
Where the fire strategy allows a choice between EI glass and an E or EW product with other measures, coordinate early with the sprinkler design, because consultants sometimes trade one against the other within what the code allows.
Fire rated glazing in the UAE must be supported by fire test evidence for the full assembly and accepted under the UAE Fire and Life Safety Code; products on the civil defence list need a UAE Certificate of Compliance for the model and factory, and in Dubai fire-resistant doors and facade systems also go through Emirates Safety Laboratory evaluation. Checked in October 2026.
| Requirement | Applies to | Authority |
|---|---|---|
| UAE Fire and Life Safety Code of Practice | Fire rating of walls, doors and facades, and therefore of the glazing in them | UAE Civil Defence, enforced by each emirate |
| UAE Civil Defence Certificate of Compliance | Fire and life safety products on the civil defence list, per model and factory | Civil defence approved certification bodies |
| Emirates Safety Laboratory evaluation (Dubai) | Fire-resistant doors, and cladding and facade systems | Dubai Civil Defence through ESL |
| EN 13501-2 classification, EN 14449 product standard, BS 476-22 | European and British route for glass and glazed assemblies | CEN and BSI, tested by accredited labs |
| ASTM E119, UL 263, NFPA 257, UL 9, UL 10C | US route for fire-resistive walls, fire windows and door vision panels | ASTM, UL, NFPA |
Two checks avoid most rejected submittals. First, match the test report to what you are building: glass make-up, maximum pane size, frame system and the wall type it was tested in. Second, confirm whether your glazed screen falls under the civil defence product list or ESL in its own right, or is approved as part of a door or facade system. Our UAE Civil Defence approval guide covers how certificates are tied to model and factory; confirm the route with the civil defence authority in your emirate.
UAE fire glazing is supplied by international glass makers through processors and distributors, and by facade and partition fabricators who hold the tested frame systems. The fabricator usually carries the approval risk, so choose one whose test evidence covers your exact system.
AGC makes the Pyrobel, Pyrobelite, Pyrobel-T and Pyropane fire-resistant glass ranges. Saint-Gobain, through its Vetrotech business, makes CONTRAFLAM, PYROSWISS and VETROFLAM and has shown its butt-jointed CONTRAFLAM Structure at Dubai facade exhibitions. Schüco offers aluminium fire-rated door, screen and facade systems, including the FW 60+ BF facade rated EI30 and EW30. Frame systems sit within the wider aluminium doors and windows market, and rated vision zones in towers are often part of a glass curtain wall package. Glazed fire doors held open for daily traffic must close when the fire alarm system signals.
Ask bidders for the classification report and test report for the complete assembly, the UAE CoC or ESL certificate where it applies, maximum pane sizes, service temperature and UV limits, and installation and inspection records. For competing quotes on one design, post your requirement to UAE suppliers.
The class and duration drive most of the cost: E glass is the cheapest, EI 60 and above the most expensive, and pane size and frame system move it further. Lead time depends on whether the glass is cut locally from stock sizes or made to order abroad.
Order early, because fire glass is cut to size after the frame survey and cannot be trimmed on site.