An automatic transfer switch (ATS) moves a UAE building or plant load from the mains to a generator or second feeder when the supply fails, then moves it back. This page explains ATS types, switching classes, conformity rules and heat limits for the UAE, and lists brands that make them so you can specify and request quotes.
0 suppliers found
Skip the search. Post your requirement and we'll connect you with verified automatic transfer switches suppliers who quote for your order directly.
Tell us about automatic transfer switches in UAE and receive competitive quotes from verified suppliers — free, fast, and no obligation.
Which switchgear and panel brands Gulf projects specify, what IEC 61439 design verification and forms of separation mean, how heat affects ratings, and the UAE and Saudi rules.
An automatic transfer switch is a controlled switching device that senses a failure of the normal supply, starts or calls the standby source, and moves the load across without an operator. It is the link between the incoming utility feed and the standby generators described under switchgear and panels for UAE projects, and it is the part that decides whether a hospital ward, data hall or pump station sees a short blink or a long outage.
The controller watches voltage and frequency on the normal source. When it detects a failure, it transfers the load to the standby source, and it retransfers once the normal supply is stable again. The main variations are how the transfer is made and how the unit is built.
| Type | Typical UAE use | Key specification points |
|---|---|---|
| Open transition (break before make) | Offices, retail, general building services, pumps and lifts that tolerate a short interruption | The two sources never overlap; adjustable transfer delays; neutral handling |
| Closed transition (make before break) | Hospitals, data centres, plants where a blink is costly | Brief overlap of both sources, so it needs utility approval and synchronism checks |
| Soft load transfer | Large loads and high-demand plants | Load is balanced between sources during the move |
| Bypass isolation | Critical sites that cannot shut down for maintenance | Lets the ATS be tested or serviced while the load stays supplied |
| Single phase or three phase | Villas and small shops against towers and factories | Pole count (3 or 4), current rating, enclosure rating |
These categories come from the way ATS makers describe their ranges, and they overlap: a hospital unit can be closed transition with a bypass. Pick the transition type from what the load can tolerate, then pick the build.
PC and CB are the two construction classes you will see on ATS data sheets that follow IEC 60947-6-1, the low voltage standard for transfer switching equipment. One vendor guide describes a PC class unit as able to make and withstand short-circuit current but not to break it, which means it relies on an upstream breaker or fuse to clear a fault. A CB class unit is built on circuit-breaker switching units, can break short-circuit current within its rating and can carry its own overcurrent protection.
In practice, PC class devices are more compact and cost less, and suit generator changeover on a sub-distribution board where a properly coordinated upstream device already exists. CB class devices are bigger and dearer and fit main incomers and points with high fault current. Whichever you choose, the data sheet should state the short-circuit withstand rating of the ATS with its upstream device named, because a higher current rating does not mean a higher short-circuit rating. Ask the supplier for the coordination table, not only the nameplate.
Vendor guides may differ on details, so treat the standard and the manufacturer's certified documentation as the final word. Related equipment that sits on the same bus is covered under low voltage switchgear for UAE buildings and distribution boards.
The Gulf climate hurts transfer switches through temperature, dust and condensation, mostly in the electronics and the enclosure rather than the contacts. A unit sits idle for months, then has to move a full load on the day the mains fail, often in a hot plant room.
Pair the switch with its power source: diesel generator sets for standby power in most buildings, or gas sets at some plants, and UPS systems for the loads that cannot wait for the generator to start.
As of 2026, there is no single rule that names transfer switches on their own, so the requirements come from the standard on the data sheet, the conformity regime for regulated products and the project specification.
| Requirement | Applies to | Authority or source |
|---|---|---|
| IEC 60947-6-1 (transfer switching equipment) | ATS data sheets, PC or CB class | IEC; quoted on project specifications and manufacturer literature |
| UAE certificate of conformity (ECAS) | Products subject to technical regulations | MoIAT; check the regulated product list for your item before importing |
| Explosion protection certificate | ATS or control gear in a classified area | MoIAT scheme for hazardous-area equipment |
| Utility and authority approval for parallel operation | Closed transition and any generator that can export | The local distribution company |
| Owner or operator vendor approval | Hospital, data centre and oil and gas projects | The client's approved manufacturer list |
MoIAT describes its conformity service as a UAE certificate of conformity for products that fall under technical regulations, and the application asks for a valid trade licence and a test report from an accredited laboratory. Whether a particular ATS is on the regulated list is a question for the supplier and MoIAT, so ask for the answer in writing with the quotation. Our guide to ECAS and EQM product conformity in the UAE explains how the registration works for imports.
Closed transition schemes deserve extra care. Because both sources are connected for a moment, the utility may need to approve the scheme before it runs, so raise this with the engineer early rather than at commissioning.
ATS equipment reaches the UAE through switchgear makers, generator brands that bundle a matching switch, and panel builders that fit imported switching devices into locally built cabinets. Generator makers usually sell an ATS tuned to their own controller, which keeps the start signal and the transfer logic from the same maker.
Manufacturer, distributor or stockist? Small three-phase units to a few hundred amps, and common controllers, are often held in Dubai and Sharjah. Large units, closed transition schemes, bypass isolation versions and anything certified for a classified area are built to order and usually arrive through Jebel Ali or Khalifa Port. Confirm the distributor is authorised by the maker, because warranty and firmware support depend on it. Our guide on sourcing industrial suppliers in the UAE and Saudi Arabia covers how to check that.
Price follows current rating, pole count, class and the extras around the switch. A compact PC class unit on a small generator is a stock item; a large CB class unit with a bypass, a closed transition controller and an enclosed floor-standing cabinet is a project order.
Ask every supplier for lead times in writing and for the ex-works date separate from shipping, since factory loads change. To compare quotes on a list of switches with ratings, transition type and enclosure, post your requirement.
How to specify an ATS or changeover switch for a standby generator: transition types, 3 vs 4 pole, PC and CB classes, AC-33 ratings, bypass-isolation, Abu Dhabi and SEC requirements and a checklist.
Perkins is a Caterpillar engine subsidiary; Cummins builds engines, complete gensets and alternators. How their generator engines compare by kVA range, packager, support and what to ask in a quote.