Waterproof membranes in Saudi Arabia are the bitumen sheets, single-ply synthetic sheets and liquid polyurethane coatings that seal concrete roofs on homes, schools, mosques, malls and industrial buildings. This page covers the membrane types used in the Kingdom, how Riyadh heat and coastal humidity change the choice, the SASO regulation and certificates that apply, how to compare Saudi suppliers, and what moves price and delivery.
0 suppliers found
Skip the search. Post your requirement and we'll connect you with verified waterproof membranes suppliers who quote for your order directly.
Tell us about waterproof membranes in Saudi Arabia and receive competitive quotes from verified suppliers — free, fast, and no obligation.
In Saudi Arabia, waterproof membranes are bought as part of roofing systems for Saudi projects, usually by a specialist applicator who lays the membrane together with roof insulation on a concrete slab. The Kingdom has local bitumen membrane factories as well as importers of European systems, so certification and origin matter as much as product type. Regulatory points below were checked in October 2026.
Saudi roofs are mostly sealed with polymer-modified bitumen sheets, made in the Kingdom and imported, with single-ply PVC or TPO on large commercial roofs and liquid polyurethane where details are complex. The choice follows the roof build-up and whether the membrane will see the sun.
| Membrane | Typical Saudi application | Points to fix in the specification |
|---|---|---|
| SBS bitumen sheet (torch-on) | Housing, schools and government buildings, under insulation or screed | Thickness, polyester or glass carrier, one or two layers, SASO certificate against SASO GSO EN 13707 |
| APP bitumen sheet with mineral cap | Roofs left exposed, small commercial and industrial roofs | Heat resistance, mineral granule colour, lap treatment, UV data |
| Self-adhesive bitumen sheet | Roofs where open flame is restricted, such as occupied buildings and plants | Primer, application temperature range, protection layer |
| PVC or TPO single-ply | Malls, warehouses, sports halls, metal deck roofs | Thickness, fixing method, welded seams, colour, EN 13956 test data |
| Liquid polyurethane or polyurea | Roof refurbishment, plant roofs, balconies and complex details | Dry film thickness, top coat, European Technical Assessment and working life |
Below-ground and tank waterproofing, where sabkha soils and saline groundwater drive the choice, is covered under Saudi waterproofing systems and its pages on bituminous waterproofing membranes and liquid-applied waterproofing.
Inland Saudi roofs, in Riyadh, Qassim and Hail, face intense sun, wide day to night temperature swings and dust storms; coastal roofs in Jeddah, Dammam and Jubail add humidity and salt. Heat and UV age exposed bitumen, movement opens laps at upstands, and dust spoils adhesion during installation.
Large daily swings expand and contract the slab and the membrane, so the weak points are upstands, parapet corners and expansion joints. Specify reinforced corners, a membrane with good cold flexibility as well as heat resistance, and protection over the sheet, either insulation and pavers or a mineral cap with a reflective coat. After a dust storm, roofs must be cleaned and re-primed before work continues.
On the Red Sea and Gulf coasts, high humidity and dew on early morning slabs affect liquid systems most: moisture-curing polyurethane can foam or lose adhesion on damp substrates. Ask the maker for its dew point and substrate moisture limits and check them on site. Salt deposits on roofs near the sea should be washed off before priming.
Because the roof carries much of the cooling load of low-rise buildings, Saudi roofs combine the membrane with insulation to meet the Saudi Building Code energy requirements. Where the membrane goes under the insulation, it is protected from sun; where it goes on top, as on some metal deck roofs, choose a sheet rated for exposure and a light colour.
SASO's Technical Regulation for Building Materials, Part 2, which covers insulation and cladding materials, lists bituminous roof waterproofing sheets against SASO GSO EN 13707. Products in that regulation need a certificate of conformity from a SASO notified body, and each imported shipment needs its SABER certificate.
| Requirement | Applies to | Authority |
|---|---|---|
| Technical Regulation for Building Materials, Part 2, item 17: roof bituminous sheets to SASO GSO EN 13707 | Bitumen roof waterproofing sheets | SASO |
| Items 18 and 19: bitumen and plastic vapour control sheets to SASO GSO EN 13970 and SASO GSO EN 13984 | Vapour control layers under roof insulation | SASO |
| Certificate of conformity, Type 3 model (Article 6/2) | Products in Part 2 other than cladding | SASO notified bodies, issued through SABER |
| Shipment certificate for each consignment | Imported regulated products | SABER platform |
| EN 13956 test data | PVC, TPO and EPDM single-ply sheets (not named in Part 2; confirm the route with a notified body) | Project specification |
| Saudi Building Code, including the energy conservation requirements for roofs | The full roof build-up | Saudi Building Code (SBC) |
Part 2 also requires a technical file to accompany the product. Single-ply sheets and liquid systems are not listed by name in the Part 2 annex we checked, so ask a notified body, or the importer, how the HS code is treated on SABER before ordering. Our guide to SASO and SABER certificates explains product and shipment certificates in more detail.
Choose a supplier who can show the SASO certificate for the exact product and factory, and who works with trained applicators that will sign a system warranty. Saudi factories have the advantage of certified local production and short delivery; importers often bring wider single-ply and liquid ranges.
Brands carried here include Awazel, a Saudi maker of SBS and APP torch-on and self-adhesive membranes; Sika bitumen, single-ply and liquid roof systems; Fosroc bituminous and liquid membranes; Index polymer-bitumen sheets; Danosa SBS sheets and synthetic membranes; Soprema bituminous and PVC or TPO sheets; Alchimica Hyperdesmo liquid polyurethane membranes; and Dr. Fixit liquid-applied and cementitious coatings.
Coordinate the membrane with the curbs of skylights and smoke vents and with any canopies built from metal roof sheeting. Our supplier vetting guide lists wider checks, and you can post your waterproofing requirement with roof areas and the project city to receive offers.
In Saudi Arabia the membrane price follows the system (layers, finish, liquid film thickness) and the warranty, while lead time depends mostly on whether the product is made in the Kingdom or imported and certified per shipment.
How one-component and two-component polyurethane, PU/polyurea hybrids and hot-spray pure polyurea differ, where each suits Gulf roofs, decks, wet areas and tanks, and what the data sheets and approvals should show.
How to choose a roof waterproofing build-up for Gulf heat, why roofs leak at falls, outlets, upstands and plant bases, how to test a finished roof, and what to put in the warranty and maintenance plan.
How to waterproof basements under high water tables and concrete water tanks: positive vs negative side, pre-applied bonded sheets, crystalline and bentonite, joints and service entries, potable linings and dewatering.