Thermal spray coating in the UAE melts metal or ceramic feedstock and sprays it onto a prepared surface, either as zinc and aluminium corrosion protection for steel or as hard, wear and heat resistant overlays on machine parts. This page explains the processes, ISO 2063 requirements, preparation, and how to pick an applicator.
0 suppliers found
Skip the search. Post your requirement and we'll connect you with verified thermal spray coating suppliers who quote for your order directly.
Tell us about thermal spray coating in UAE and receive competitive quotes from verified suppliers — free, fast, and no obligation.
Thermal spray coating heats a wire or powder to a molten or semi-molten state and propels it onto a surface, where it builds up as a layered coating. In the UAE it is bought as a service from workshops and site contractors, and it is a distinct branch of surface treatment in the UAE, next to galvanizing and blasting. Two families matter to buyers: corrosion protection of structural steel, and engineered coatings for wear, erosion and heat.
| Process | Feedstock | Typical UAE use |
|---|---|---|
| Arc wire spray | Zinc, aluminium, alloy wires | Offshore and marine steel, large tanks and structures |
| Flame spray | Wire or powder | Repair, build-up, lower-cost coatings |
| HVOF (high velocity oxy-fuel) | Tungsten carbide and other powders | Pump shafts, valve parts, rolls, hard chrome replacement |
| Plasma spray | Ceramic and metal powders | Heat and wear barriers on turbine and process parts |
| Twin-wire arc | Two alloy wires sprayed together | Composite wear coatings |
Equipment makers describe all four of arc wire, flame, plasma and HVOF as part of their thermal spray offer, with powders including tungsten carbide, ceramic, stellite and inconel, and at least one maker runs a dedicated thermal spray division at the Jebel Ali Free Zone with on-site coating capability.
ISO 2063-1:2019 covers corrosion protection of iron and steel by thermally sprayed zinc, aluminium or their alloys. It addresses planning and design of the protection, terminology and corrosion behaviour, coating properties such as thickness, minimum adhesive strength and appearance, and the tests. It applies from −50 to +200 degrees C service, with the sealer's temperature limit also considered. It excludes hot dip galvanizing, electroplating, paints and heat-resistant aluminium coatings; manufacturing requirements are in ISO 2063-2.
When your specification quotes ISO 2063, ask the applicator to state the zinc or aluminium alloy, nominal thickness, adhesion test method and whether a sealer or topcoat is part of the system.
Choose thermal spray when the steel is too large for a bath, already assembled, or must stay cool. It has no kettle size limit, it can be applied in the shop or on site, and it does not subject the part to zinc bath temperatures. Hot dip galvanizing is better for batches that fit the bath, because it coats insides, edges and welds in one dip under ISO 1461.
Compare hot dip galvanizing, then see industrial protective coatings for the paint sealers often used above a sprayed layer.
Thermal spray needs a clean, rough, dry surface, so it begins with abrasive blasting. Sprayed coatings bond mechanically, so the blast profile is critical, and the coating must go on before rust returns. Typical specifications ask for a very high blast cleanliness, such as Sa 2½ to Sa 3 or SSPC-SP 5 and SP 10, and the project documents set the exact grade. Graco's comparison shows how those grades relate.
In UAE humidity, blasted steel flash-rusts fast, so spray within hours and only with steel above the dew point. Start with shot blasting and sand blasting, and ask for blast records. ISO 12944-2 classifies the environment, which helps the specifier set thickness and sealing.
There is no single UAE licence for thermal spray work; the specification, the owner's approved list and the applicator's procedures decide. Checked as of 2026; confirm with the client.
| Requirement | Applies to | Set by |
|---|---|---|
| ISO 2063-1:2019 and ISO 2063-2 | Zinc and aluminium sprayed corrosion protection | ISO |
| Blast cleanliness grade and profile | Preparation before spraying | Project specification |
| Applicator procedure and operator qualification | Process control for all spray types | Client or OEM specification |
| Environmental and safety permits | Fume, dust, noise and waste from the shop | Emirate regulators and client HSE |
Inspection of thickness and adhesion is covered under coating inspection services. For oil and gas rotating equipment, ADNOC and OEM repair specifications may call for a named process and qualified procedure; request the current document from the owner.
Choose on the process you need and the evidence of control. Corrosion spraying and HVOF wear coating are different skills, and few shops do both.
The guide to sourcing industrial suppliers in the UAE and Saudi Arabia adds general checks, and you can post your requirement for thermal spray coating to collect offers. Also see powder coating services for small steel items that do not need metal spray.
Price depends on the process, the feedstock, coating thickness, part size and finishing. Zinc or aluminium wire sprayed on large structures is priced by area; HVOF carbide is priced per part, driven by powder cost, grinding and masking. Site work adds mobilisation, access and dehumidification.
Lead time follows blasting and spraying capacity, finishing steps and testing. Book blasting, spraying and sealing together, because delays between them risk rusting and re-blasting.