Pressure gauges in the UAE are local dial instruments that show line or vessel pressure, mostly Bourdon tube gauges built to EN 837-1 or ASME B40.100, and buyers choose them by dial size, range, accuracy class, wetted material and case filling. This page explains the types, UAE heat and vibration limits, standards and calibration as of 2026, and who supplies them.
0 suppliers found
Skip the search. Post your requirement and we'll connect you with verified pressure gauges suppliers who quote for your order directly.
Tell us about pressure gauges in UAE and receive competitive quotes from verified suppliers — free, fast, and no obligation.
A pressure gauge is a mechanical or digital dial instrument that shows pressure at the point of measurement without power or a control system. Most UAE orders are for Bourdon tube gauges, which use a curved metal tube that straightens as pressure rises and moves a pointer. Gauges belong to pressure instruments for UAE plants and are fitted to pump discharges, filters, compressor skids, boiler rooms and fire pump sets.
| Type | Typical UAE use | Key specification points |
|---|---|---|
| Bourdon tube gauge, stainless steel | Process lines in refineries, gas plants and water treatment | Case size, range, class, safety level, connection thread, wetted material |
| Liquid-filled gauge | Pumps, compressors and any vibrating line | Glycerine or silicone fill, temperature window |
| Safety pattern gauge | Steam, gas and high-pressure lines near people | Blow-out back, solid front, safety glass |
| Gauge with diaphragm seal | Corrosive, viscous or crystallising media | Seal material, fill liquid, assembled accuracy |
| Gauge with switch contacts | Local indication with an alarm contact | Contact type, set points, enclosure |
WIKA's stainless steel gauge data sheet PM 02.02, for example, covers models 232.50 and 233.50 in 63, 100 and 160 mm sizes with scale ranges from 0 to 0.6 bar up to 0 to 1,600 bar, and lists related versions with switch contacts and mounted diaphragm seals. Gauges give local reading only; when the value must go to a control room, use pressure transmitters, and for a simple alarm or trip use pressure switches.
Choose the range so normal working pressure sits around the middle of the scale, pick the accuracy class to suit the task, and match case size and filling to vibration. Gauge accuracy is a percentage of full scale, so a wide range gives a coarse reading.
The Gulf standard GSO EN 837-2:2021, "Pressure gauges, selection and installation recommendations", adopted on 1 July 2021, covers gauges with a mechanical measuring system and is meant to help users select, install and use them safely. Ask your consultant whether it is called up on your project.
Heat limits the case filling and the dial, and vibration shortens the life of an unfilled gauge, so specify the fill and the mounting for the real site. The same WIKA data sheet shows how the limits stack up.
For the stainless steel gauge, ambient temperature limits are minus 20 to plus 60 °C with glycerine filling and minus 40 to plus 60 °C unfilled or silicone filled, and medium temperature reaches 200 °C for unfilled instruments and 100 °C with either fill. The data sheet adds a temperature error of up to 0.4 percent of full scale per 10 °C away from the 20 °C reference. A gauge in direct August sun on a pipe rack in Ruwais or Jebel Ali can reach the 60 °C ceiling, so ask for a sunshade or a siphon or remote mount on hot lines.
The data sheet describes the liquid-filled model 233.50 as suited to high dynamic pressure loads and vibrations. For reciprocating pumps add a snubber or restrictor, and mount the gauge on a bracket or capillary away from the vibrating line.
Salt air attacks brass movements and painted steel cases, so choose stainless steel in Fujairah, Khalifa Port and Jebel Ali, keep the breather plugs in place and replace gauges with fogged windows or damaged cases.
In the UAE, pressure gauges are bought to the design standards in the project specification, not to a single mandatory product rule. Mechanical gauges are not electrical equipment, so the ECAS-Ex scheme generally does not apply; check the specification as of 2026.
| Requirement | Applies to | Authority |
|---|---|---|
| EN 837-1 and ASME B40.100 | Design, accuracy and safety features of Bourdon tube gauges; many makers build to both | CEN and ASME, called up by the purchaser |
| GSO EN 837-2:2021 | Selection and installation recommendations for mechanical gauges | GSO (GCC standard) |
| ECAS-Ex certificate | Electrical equipment in explosive atmospheres, so applies to gauges with electric contacts or electronics, not purely mechanical gauges | MoIAT, through notified bodies |
| ATEX marking for non-electrical equipment | The WIKA data sheet lists an optional ATEX marking (Ex h) for the mechanical gauge; ask whether your owner wants it | Owner or project specification |
| ISO/IEC 17025 accredited calibration | Calibration certificates for gauges in custody, quality or safety duties | EIAC lists calibration laboratories among its accreditation services |
Intertek describes ECAS-Ex as the UAE scheme for electrical equipment in potentially explosive atmospheres. The guide to ECAS and EQM conformity in the UAE explains the wider conformity system. For calibration, check the laboratory's scope lists pressure and your range, and that the certificate states uncertainty. Plants that calibrate in-house use calibration equipment, and many gauge installations sit beside temperature instruments on the same skid.
Pressure gauges in the UAE are sold by manufacturer subsidiaries, authorised distributors and industrial stockists, with local stock concentrated in Dubai and Abu Dhabi.
Ask for the data sheet, material certificate (for example EN 10204 3.1 where the project requires it), calibration certificate and written confirmation of the case fill and temperature range. The guide to sourcing industrial suppliers in the UAE and Saudi Arabia covers authorisation checks.
Price depends on case material, size, accuracy class, wetted parts and options such as fill, seals and certificates, and lead time on whether the exact range and connection is stocked.
To request quotes, post your requirement with dial size, range and unit, connection, material, case fill, accuracy class and any certificates.