Multifunction calibrators in the UAE are handheld instruments that source and measure current, voltage, resistance, thermocouple and RTD signals so technicians can test a whole loop. This page covers the functions to compare, accuracy and logging, summer heat and radio-field limits, ECAS-Ex and accreditation rules, and how to choose a supplier.
0 suppliers found
Skip the search. Post your requirement and we'll connect you with verified multifunction calibrators suppliers who quote for your order directly.
Tell us about multifunction calibrators in UAE and receive competitive quotes from verified suppliers — free, fast, and no obligation.
A multifunction calibrator is a handheld instrument that sources and measures several electrical signals in one case, typically current, voltage, resistance, thermocouple and RTD signals, frequency and pulses, so a technician can test a loop from one device. It belongs to the calibration equipment category in the UAE, and it is the tool commissioning engineers carry on new plants and maintenance crews carry on routine loop checks at power, water, oil and gas and manufacturing sites.
| Function | What it is used for | Point to check |
|---|---|---|
| Source and measure mA (4 to 20 mA) | Simulating a transmitter to test a controller input, or reading a transmitter output | Accuracy, loop power of 24 V, maximum load current |
| Source and measure voltage | Checking 0 to 10 V inputs, millivolt signals and power supplies | Ranges, input impedance, overload protection |
| Resistance and RTD simulation | Testing temperature transmitters and indicators with no probe | Sensor types such as Pt100, wire configurations |
| Thermocouple simulation and measurement | Testing thermocouple inputs, with cold junction compensation | Type list, cold junction accuracy |
| Frequency and pulse | Flow meters, speed sensors, counters | Output range, pulse count |
| Stored procedures and logging | Repeatable as-found and as-left records | Memory, software, export format |
When pressure is part of the test, add a pump or modules; see pressure calibrators. When a probe itself must be checked in a controlled temperature, use temperature calibrators. The instruments at the other end of the loop are described under instrumentation and process control in the UAE.
Choose by the signals you test every week, then by accuracy, ruggedness and records. A calibrator that covers everything but is awkward to carry will stay in the workshop, so match the unit to the job rather than to the longest specification list.
These instruments are battery-powered electronics with a stated working band, and UAE plants test them at the edge. The CA71 is specified for 0 to 50 degrees C and 20 to 80 percent humidity without condensation, and runs on four AA batteries with a stated life of about 12 to 40 hours depending on use. The CPH7000 operates from minus 10 to plus 50 degrees C, and its charging range is 0 to 40 degrees C outside hazardous areas.
As of 2026, the key UAE points are hazardous-area certification when the calibrator is used in a classified zone, and traceable calibration of the calibrator itself. The 2022 MoIAT regulated-products list I checked does not name multifunction calibrators, so confirm with MoIAT or your importer whether a model needs registration.
| Requirement | Applies to | Authority or source |
|---|---|---|
| ECAS-Ex certificate of conformity | Intrinsically safe calibrators used in explosive atmospheres | MoIAT, IECEx-based, valid 1 or 3 years |
| ISO/IEC 17025 accredited calibration | The calibrator as a reference instrument | Laboratories accredited by EIAC |
| National electrical standards | Traceability for voltage, current and resistance | Emirates Metrology Institute |
| EMC and low-voltage declarations | Battery or mains charged electronics | Manufacturer declarations |
WIKA offers the CPH7000 in a hazardous-area version, tested to ATEX and IECEx. Intertek describes ECAS-Ex as a MoIAT scheme based on IECEx under Cabinet Resolution No. 23 of 2016; see the guide to ECAS and EQM product conformity in the UAE. Gulf News reports that the Emirates Metrology Institute in Abu Dhabi holds national standards including electrical quantities, which lets strategic industries calibrate at home.
Multifunction calibrators are sold through manufacturer offices, authorised distributors and instrument stockists. Look for a supplier that stocks accessories such as leads, fuses and batteries, and can recalibrate the unit in the UAE.
Two brands on ListGCC make these instruments. Yokogawa makes the CA51 and CA71 handy multifunction calibrators and the CA700 pressure calibrator, and WIKA makes the CPH7000 portable process calibrator with a built-in electrical module. Ask for the model's data sheet date, the certificate type and the lead time for batteries and leads. See the guide to sourcing industrial suppliers in the UAE and Saudi Arabia, and post your requirement if you want several quotes.
Price depends on the signals covered, accuracy, documenting software, hazardous-area certification and certificate type. A basic loop-checking unit costs far less than a documenting, intrinsically safe calibrator. Lead time is short for stocked models and longer for hazardous-area versions and special kits. Ask whether the quoted time includes the accredited certificate, and keep spare leads and fuses on the shelf so a lost lead does not stop a shutdown.