Intumescent fire coatings in the UAE are paint systems that swell into an insulating char in a fire, keeping structural steel below its failure temperature for a rated time. This page lists UAE suppliers and explains thin-film and epoxy types, how thickness is set from the section factor, which fire tests and Civil Defence checks apply as of 2026, and what drives cost and delivery.
0 suppliers found
Skip the search. Post your requirement and we'll connect you with verified intumescent fire coatings suppliers who quote for your order directly.
Tell us about intumescent fire coatings in UAE and receive competitive quotes from verified suppliers — free, fast, and no obligation.
A fact-checked comparison of Jotun and National Paints for Gulf buyers: where each makes paint, their decorative, fire, floor and marine ranges, support and the approvals to ask for.
An intumescent fire coating is a thin layer applied to steel that expands many times its thickness when heated, forming a char that insulates the steel so a beam or column keeps its load capacity for 30 minutes to several hours. In the UAE these coatings are one of the product groups within industrial paints and coatings for UAE projects, and they are the usual choice where exposed steel has to look like painted steel: airport terminals, malls, stadiums, towers with feature steelwork, and warehouse frames.
Two fire scenarios split the market. Buildings are designed for cellulosic fires, the burning of furniture and stock, tested on the standard temperature curve of EN 1363-1. Oil, gas and petrochemical plants are designed for hydrocarbon pool and jet fires, which heat steel far faster and need a different, thicker product.
| Type | Typical UAE use | Key specification points |
|---|---|---|
| Waterborne acrylic thin film | Interior steel in offices, malls, schools and terminals | Fire rating in minutes, interior dry exposure only unless topcoated, slow drying in humid air |
| Solventborne acrylic thin film | Shop or site applied steel, semi-exposed canopies and car parks | Faster drying, durability category, compatible topcoat for outdoor exposure |
| Epoxy intumescent for cellulosic fire | Offsite applied steel, external and high humidity areas, long ratings | High build, solvent free, impact resistance, rating up to about 2 to 4 hours depending on product |
| Epoxy intumescent for hydrocarbon fire | Pipe racks, vessel skirts, process structures in plants | UL 1709 rating, jet fire test to ISO 22899-1, mesh or mesh-free, owner approval |
Intumescents sit on top of a primer, so the anti-corrosion primer and any tie coat must be ones the fire test covered. The decorative or weathering topcoat often comes from the same maker's protective coating systems. For walls, doors and openings, look at fire-rated doors and the wider fire protection systems category; steel frames themselves come from structural steel fabricators, many of whom apply intumescent in the shop.
Specify an intumescent by fire rating, member size and exposure: the manufacturer then calculates a dry film thickness for each member from its assessed test data. Getting the inputs right matters more than the brand, because an under-thickness member fails the fire design even if the paint is approved.
The section factor compares the heated perimeter of a member with its cross-sectional area. Light sections with a high section factor heat up faster and need more coating than heavy sections for the same rating. The structural engineer sets the fire rating and, where the design allows, the critical steel temperature; the coating supplier returns a thickness schedule member by member. Ask for that schedule with the test standard it is based on, and check that cellular beams, hollow sections and open sections are each covered by the assessment.
Durability testing for European assessed products uses exposure categories from fully exposed outdoor (X) through semi-exposed (Y) to interior humid and interior dry (Z1 and Z2), set in EAD 350402-00-1106. Waterborne thin films suit dry, air-conditioned interiors. Semi-open car parks, canopies and coastal sites in Dubai Marina, Abu Dhabi island or Ras Al Khaimah need a product assessed for the harsher category, normally with a sealing topcoat, because condensation on summer mornings and salt in the air attack the film.
Thick intumescent coats are built up in several passes, and each pass must dry before the next. High steel temperatures, wind-blown dust and humidity on the coast all affect drying and finish. Shop application in a controlled bay, with the steel delivered coated and protected, avoids much of this; site touch-up after erection then follows the manufacturer's repair procedure. Insist on dry film thickness readings for every member, recorded against the schedule, and use independent coating inspection at hold points on large jobs.
In the UAE the required fire rating comes from the UAE Fire and Life Safety Code of Practice and the project fire strategy, and the coating must carry fire test evidence the Civil Defence authority and the consultant accept. The test standards below are the ones manufacturers cite; we checked them in October 2026.
| Requirement | Applies to | Authority |
|---|---|---|
| EN 13381-8:2013 | Contribution of reactive coatings to the fire resistance of steel beams and columns, standard curve of EN 1363-1 | CEN, assessed in a European Technical Assessment |
| BS 476 Parts 20 and 21 | Fire resistance of protected steel elements, often with third-party certification such as Certifire | BSI test methods |
| EAD 350402-00-1106 | Durability categories X, Y, Z1 and Z2 for reactive coatings | EOTA |
| UL 1709 | Rapid-rise hydrocarbon fire exposure of protected structural steel | UL Solutions |
| ISO 22899-1 | Resistance of passive fire protection to jet fires | ISO |
| UAE Fire and Life Safety Code of Practice, product approval | Fire resistance of building elements and approval of fire safety products | UAE Civil Defence and the emirate Civil Defence authorities, such as Dubai Civil Defence |
| ADNOC and EPC fireproofing specifications | Passive fire protection on ADNOC group plants | ADNOC companies and their contractors |
EN 13381-8 covers I and H sections and hollow sections, extends to angles, channels and tees of the same section factor, and excludes sections with web openings, which need their own assessment. The test data feed the steel fire design rules of EN 1993-1-2. For approvals, practice differs between emirates, so ask the supplier for the Civil Defence approval or certificate for the exact product, check whether the authority requires test reports from a laboratory it recognises, and confirm the route with the authority as of 2026. Our guide to UAE Civil Defence approval explains certificates of conformity, and the ECAS and EQM conformity guide covers MoIAT product schemes.
Buy intumescents from the manufacturer's UAE office or an authorised distributor, not an open-market stockist: the thickness calculation, the approval and the warranty all depend on a named product, batch and applicator. A cheaper tin without a thickness schedule is not a fire rating.
Makers of fire protection coatings include Jotun, with the SteelMaster range for cellulosic fire and Jotachar epoxy products for hydrocarbon fire; Hempel, whose Hempafire XTR 100 is a two-pack epoxy intumescent for hydrocarbon pool and jet fires; PPG, with the Steelguard cellulosic range in waterborne, solvent-based and solvent-free forms; Sherwin-Williams, with the Firetex range; and Promat, a passive fire protection specialist whose boards and coatings are an alternative where coatings alone are too thick.
Ask each bidder for:
Applicators are listed under painting and coating contractors in the UAE. To get comparable quotes, post your fire coating requirement with the steel tonnage or member list, ratings and exposure. The supplier sourcing guide covers checking a distributor's authorisation.
The cost of intumescent protection in the UAE rises with the fire rating and with lighter steel sections, because both increase the thickness to be applied. Compare cost per member or per tonne at the scheduled thickness, never price per litre.
Common thin films are usually stocked locally. Thickness schedules need the steel drawings, and epoxy fireproofing for plants, unusual ratings and products still awaiting approval can take weeks longer.
How to specify intumescent fire protection for steel in the Gulf: product types, fire curves and test standards, thickness schedules, inspection, and civil defence and SBC questions to ask.
Which paint and coating brands make paint in the UAE and Saudi Arabia, how to specify decorative, epoxy, anti-corrosion and fire coatings, and the MoIAT, Dubai and SASO rules that apply.