Instrumentation cables in the UAE carry signals from field transmitters to control systems in refineries, gas plants, power and desalination stations. This page explains OS and IOS screening, pairs and triads, armour, EN 50288-7 replacing BS 5308, heat effects, MoIAT and owner approvals as of 2026, linked cable makers and what drives price and lead time.
0 suppliers found
Skip the search. Post your requirement and we'll connect you with verified instrumentation cables suppliers who quote for your order directly.
Tell us about instrumentation cables in UAE and receive competitive quotes from verified suppliers — free, fast, and no obligation.
Who makes power cable for UAE and Saudi projects, which IEC and BS standards apply, how 50 °C heat changes cable size, and what MoIAT, Civil Defence, SABER and SEC require.
Instrumentation cables carry low-level analogue and digital signals from field transmitters, switches and analysers to control systems, using twisted pairs, triads or quads with screening to keep noise out. In the UAE they are part of the cables and wiring family for the UAE and are bought for refineries, gas plants, power and desalination stations, and building management systems.
| Type | Typical UAE use | Construction notes |
|---|---|---|
| Pairs, overall screened (OS) | 4 to 20 mA loops in clean, short runs | One collective aluminium and plastic foil screen with drain wire |
| Pairs, individually and overall screened (IOS) | Multi-pair trunk cables to marshalling cabinets | Foil screen on each pair plus an overall screen; reduces crosstalk |
| Triads and quads | RTD three-wire and four-wire sensors, bridge circuits | Same screening options as pairs |
| Armoured instrumentation cable | Buried and outdoor routes in process areas | Steel wire armour over the bedding, PVC or LSZH outer sheath |
| Fire resistant instrumentation cable | Emergency shutdown and fire and gas signals | Circuit integrity construction at 300 V and 500 V grades |
Instrumentation cable shares a route with heavier cables only through careful design. Main feeders are on power cables, interlocks and starters on control cables, and the screens and armour end in cable glands and lugs. Safety signals use fire resistant cables.
Choose from signal type, noise environment and route, in that order. The European standard EN 50288-7 is specifically written for instrumentation and control cables and replaced BS 5308, according to Helukabel's explanation; it sets a standard rating of 300 V (90 V and 500 V versions exist), conductors from 0.5 to 2.5 mm2 and insulation in PVC, PE or XLPE.
Hot routes raise conductor resistance and cable sheaths soften, so check temperature limits and loop resistance, and keep instrument cables away from heavy power circuits. The Nexans cable listing gives an operating range of minus 20 to 60 degrees C with a maximum conductor temperature of 90 degrees C, a reminder that sun-heated trays on UAE plants can approach the upper limit.
As of 2026 instrumentation cable is specified to EN 50288-7 or an equivalent, with flame test classes from IEC 60332-3 and owner approvals for oil and gas work. MoIAT conformity applies to LV cables sold in the UAE where in scope.
| Requirement | Applies to | Authority or body |
|---|---|---|
| EN 50288-7 | Instrumentation and control cable, OS and IOS types | CENELEC; BS EN adoption in the UK |
| IEC 60332-3-22 Category A | Flame propagation of bunched cables | IEC |
| BS 5308 (replaced by EN 50288-7) | Older specifications still quoted in some tender documents | BSI |
| MoIAT conformity | LV cable on the UAE market, depending on scope | MoIAT (ECAS or EQM) |
| Owner vendor approval | Refinery, gas and utility projects | The owner's procurement and inspection teams |
Check old tender documents: a specification that cites BS 5308 expects the buyer to name the current equivalent. The ECAS and EQM guide explains the MoIAT route.
Test each pair for continuity, insulation resistance and screen continuity after pulling, and record the results against the loop list. Signal faults found at the control system are far more expensive to chase than faults found on the drum.
Most signal complaints trace to installation, not to the cable standard. The usual causes are listed below, and every one of them is avoidable at the design and pulling stage.
Write these into the installation specification and have the inspector check them.
Instrumentation cable reaches UAE plants from international groups and regional cable makers, usually on a project basis with drum test certificates. Makers with documented ranges are linked here.
Ask for the exact construction data sheet and the type test report. The sourcing guide shows what a reliable supplier provides.
Copper weight, the number of screened pairs and the armour drive price; lead time depends on whether your pair count and conductor size is a standard construction.
With the loop list and routes ready, post your requirement for quotes.