Coriolis flow meters measure mass flow, density and temperature directly, and UAE buyers use them for hydrocarbon transfer, fuel oil, chemicals and food lines. This page explains the meter types, how to size and install them for UAE conditions, which API, OIML and MoIAT requirements apply as of 2026, and which brands supply them.
0 suppliers found
Skip the search. Post your requirement and we'll connect you with verified coriolis flow meters suppliers who quote for your order directly.
Tell us about coriolis flow meters in UAE and receive competitive quotes from verified suppliers — free, fast, and no obligation.
A Coriolis flow meter measures mass flow directly by vibrating one or more tubes and sensing how the moving fluid twists them; it also reports density and temperature. UAE buyers specify it for hydrocarbon loading and transfer, fuel oil and LPG, chemical dosing and batching, and food and beverage lines. It is one of six meter principles in flow measurement instruments for the UAE.
Emerson describes the principle in one line: as fluid moves through the sensor it creates a measurable twist in the vibration, and the phase shift is converted into mass flow. The same sensor yields liquid density and process temperature, so one meter can replace a volume meter, a densitometer and the compensation calculation. That is why Coriolis is often compared with turbine and positive displacement meters on liquid hydrocarbons, where it has no moving parts exposed to the fluid.
| Version | Typical UAE use | What to specify |
|---|---|---|
| Bent-tube or straight-tube process meter | Fuel oil, lubricants, solvents, chemical transfer | Line size, wetted material, pressure rating, pressure drop at maximum flow |
| Hygienic meter | Dairy, juice, bottled drinks and syrup lines | Clean-in-place compatibility, hygienic connections, drainable tubes |
| Custody transfer meter | Terminals, loading arms, fiscal skids | Accuracy class, uncertainty statement, proving or verification method, flow computer |
| High-pressure or gas meter | Compressed gas, CO2, hydrogen filling | Pressure limit, gas flow range, pressure compensation |
| Low-flow meter | Dosing skids, laboratory and pilot plants | Minimum flow, zero stability, accuracy at the bottom of the range |
Coriolis is the meter to choose when mass or density matters. For conductive water-based liquids, electromagnetic flow meters cost less. For steam and gas, vortex flow meters are common, for large pipes ultrasonic flow meters are used, for clean fuels turbine flow meters remain in service, and for simple local indication rotameters are cheaper still.
Choose a UAE Coriolis meter by fluid, flow range and installation, then check the ambient limits of the transmitter. Pressure drop and size matter more than for most other principles.
Coriolis meters are often one or two line sizes smaller than the pipe, which raises velocity and pressure drop, especially with viscous fluids such as fuel oil. Give the supplier minimum, normal and maximum flow, viscosity at operating temperature and available pump head. Do not size on the pipe diameter.
Emerson notes that with entrained gas the meter keeps measuring the mixture but density reads low because it reflects the lighter mixture, and that its G-Series is not recommended for entrained-air two-phase use because the high operating frequency can increase error. Where liquid transfer can see air or vapour, such as emptying tanks or truck loading, ask for a model proven in two-phase conditions and design out gas with air eliminators and good pump suction.
The sensor is a heavy metal body, but the electronics have temperature limits. In UAE summers, sun-loaded transmitters can overheat, so use shades or remote mounting and check the data sheet limit. Hot fluids, such as heated fuel oil, also require attention to the manufacturer's process temperature rating, insulation and thermal effects on zero.
Coriolis meters are zeroed at no-flow, and installation vibration or a partially closed valve can disturb readings. Emerson says its Smart Meter Verification can confirm meter health in situ in under 90 seconds without removing the meter from service, but also notes verification may not replace calibration, depending on site quality procedures and regulatory requirements. Ask which your project accepts.
A Coriolis meter used for process control is bought to the owner's data sheet, while one used for custody transfer or trade falls under API and OIML documents and, for regulated measurement, MoIAT legal metrology. Checked as of October 2026.
| Requirement | Applies to | Authority |
|---|---|---|
| API MPMS Chapter 5.6, 2nd edition (December 2021) | Specification, installation, verification and operation of Coriolis meters for liquid hydrocarbons | API, called up by owners |
| OIML R 117-1:2019 | Dynamic measuring systems for liquids other than water under legal metrology; accuracy class 0.3 for pipelines and 0.5 for most other systems, including fuel dispensers | OIML, applied through national legal metrology |
| Legal measuring instruments regulation (Board Chairman Decision No. 75 of 2016) | Instruments used for regulated measurements | MoIAT |
| ECAS-Ex certificate | Meter electronics and transmitters in explosive atmospheres, based on IECEx documents | MoIAT, via notified bodies |
| ISO/IEC 17025 calibration | Calibration certificates for custody or quality-critical duty | Accredited laboratory (EIAC or an ILAC-recognised body) |
The API catalogue describes Chapter 5.6 as giving guidance for the specification, installation, verification and operation of Coriolis meters used to measure liquid hydrocarbons dynamically, including information for troubleshooting. OIML R 117-1 says Coriolis, ultrasonic and electromagnetic meters are not required to undergo the endurance test applied to meters with moving parts exposed to the liquid. MoIAT lists legal measuring instruments under Decision No. 75 of 2016, with details defined in technical regulations for each instrument type, so ask MoIAT or the owner whether your measurement is regulated. For hazardous areas, read our ECAS and EQM guide.
UAE Coriolis meters are supplied by process instrument makers through their regional offices, authorised distributors and metering skid integrators. Brands that make Coriolis meters include Emerson, through Micro Motion, Endress+Hauser, KROHNE with its OPTIMASS range, Yokogawa and Foxboro from Schneider Electric.
For fiscal skids with provers, flow computers and sampling, buy through an integrator with ADNOC or terminal references. For process meters, an authorised distributor can size, supply and commission. Ask for an uncertainty estimate in writing, local calibration or verification capability, and spare transmitters. Our sourcing guide explains authorisation checks, and you can post your requirement with fluid data to compare quotes. Meters usually report to a PLC or DCS.
Price rises with line size, pressure rating, wetted alloy and accuracy class. Lead time rises with certification and with sizes not held in stock.