Laboratory centrifuges in the UAE separate samples by spinning them at high speed, from blood and urine in hospital labs to cells, DNA and crude oil water tests in research and petroleum labs. This page explains the types and the specifications that matter, how to convert rpm to g-force, which safety standard and approvals apply as of 2026, how UAE conditions affect them, and how to compare the suppliers listed below.
0 suppliers found
Skip the search. Post your requirement and we'll connect you with verified centrifuges suppliers who quote for your order directly.
Tell us about centrifuges in UAE and receive competitive quotes from verified suppliers — free, fast, and no obligation.
A laboratory centrifuge spins sample tubes in a rotor so that heavier components settle out under a force many times gravity. It is part of the laboratory equipment range for UAE labs, and the right model depends less on maximum speed than on the tubes, volumes and temperature your methods call for.
| Type | Typical use in the UAE | Key specifications |
|---|---|---|
| Micro-centrifuge | Molecular biology, DNA and RNA preparation, small-volume clinical work | Maximum RCF, capacity in 1.5 and 2 ml tubes, PCR strip adapters, refrigerated or ambient |
| Benchtop general purpose | Hospital and clinic labs: blood collection tubes, urine sediment | Swing-out and fixed-angle rotor options, adapters for your tube sizes, programme memory, lid lock and imbalance cut-out |
| Refrigerated benchtop | Cell culture, proteins, temperature-sensitive samples in research and pharma labs | Temperature range and pull-down time, rated ambient temperature, sealed buckets, plate carriers |
| Floor-standing high capacity | Blood banks, bioprocess and large-volume research | Bottle capacity, rotor range, three-phase power, heat output to the room |
| High-speed and ultracentrifuges | Research separations at very high g-force | Vacuum chamber, rotor certification and life records, service contract |
| Heated oil-testing centrifuge | Refinery, terminal and inspection labs measuring water and sediment in crude and fuel oils | Heating to the method temperature, rotor for cone-shaped tubes, explosion protection where the lab classification calls for it |
For petroleum labs, the methods most often specified are ASTM D4007 (water and sediment in crude oil by the centrifuge method) and ASTM D1796 (water and sediment in fuel oils by the centrifuge method). Check the edition your contract cites and buy a centrifuge that the maker states meets that method's speed, heating and tube requirements.
Methods specify relative centrifugal force (RCF, in x g), not rpm, because the same speed gives a different force in a different rotor. The conversion is RCF = 1.118 x 10 to the power -5 x r x rpm squared, where r is the rotor radius in centimetres to the bottom of the tube.
A rotor with a 15 cm radius at 4,000 rpm gives about 2,680 x g; a smaller rotor with a 10 cm radius at the same speed gives about 1,790 x g. When you compare quotes, ask each supplier for the maximum RCF of the exact rotor and adapter you will use, and check that your tubes are rated for it: tube ratings are listed with the products under lab consumables and reagents. A protocol written for a different rotor must be recalculated in RCF before it runs on a new machine.
Centrifuges rarely work alone. Molecular labs pair micro-centrifuges with their PCR and molecular biology equipment, and clinical labs feed separated serum to analysers covered under diagnostic equipment. Ask whether rotors and buckets can be cleaned in the lab's laboratory autoclaves, since not every rotor material tolerates steam.
As of 2026, a general laboratory centrifuge needs no product registration in the UAE; it is bought to the IEC 61010-2-020 safety standard. A model the maker labels for in vitro diagnostic use is a medical device, so ask for its Emirates Drug Establishment (EDE) marketing authorisation.
| Requirement | Applies to | Authority or standard body |
|---|---|---|
| IEC 61010-2-020:2026, particular requirements for laboratory centrifuges (with IEC 61010-1) | All electrically powered laboratory centrifuges | IEC; the fourth edition, published September 2026, replaces the 2016 edition |
| Aerosol containment testing of rotors and bucket lids | Centrifuges used for infectious or high-risk biological samples | Maker's test certificate; some rotors are certified by the UK Health Protection Agency at Porton Down |
| Marketing authorisation for medical devices | Centrifuges labelled for in vitro diagnostic use | Emirates Drug Establishment (EDE) |
| MoIAT conformity (ECAS or EQM), where a regulation applies | Some electrical products; check per model | Ministry of Industry and Advanced Technology |
| Speed and temperature verification | Centrifuges used in ISO/IEC 17025 or ISO 15189 accredited methods | Labs accredited by the Emirates International Accreditation Centre (EIAC) |
The 2026 edition of IEC 61010-2-020 is a technical revision aligned with the amended IEC 61010-1, so a tender written today may still quote the 2016 edition; ask which edition the maker's test report covers. For biological work, Yale EHS notes that sealed buckets and aerosol-tight rotors should be loaded and unloaded inside a biosafety cabinet when handling high-risk materials. Accredited labs should plan regular checks of speed with a tachometer and of chamber temperature, using tools from calibration equipment suppliers.
Heat and vibration are the two UAE factors to plan for: refrigerated centrifuges reject heat into rooms that are already hard to cool in summer, and a heavy rotor on a weak or uneven bench will vibrate and trip.
Centrifuges reach UAE labs through scientific distributors that hold rotors, adapters and spares locally. Pick a supplier for the rotor and adapter range it can deliver quickly, and for the engineer who will inspect the rotors each year.
Makers carried here include Cryste, a Korean maker of refrigerated high-speed benchtop, multipurpose and micro centrifuges; BIOBASE, which lists mini, low-speed and high-speed centrifuges; and Infitek, which makes benchtop and refrigerated centrifuges within a broader instrument line. Before you sign, ask:
Buyers can post a requirement listing tube types, volumes and RCF to get matched quotes from UAE suppliers.
Rotors and refrigeration drive the price more than the base unit. A benchtop centrifuge with one fixed-angle rotor is the entry point; adding a swing-out rotor, sealed buckets, plate carriers and refrigeration can more than double the order. High-speed and ultracentrifuges carry service contracts that matter as much as the purchase price.
Common benchtop and micro models are often in UAE stock. Floor-standing and high-speed units, and any rotor or adapter outside the standard set, are factory orders. A model sold for diagnostic use is only supplied once its EDE registration is in place.