Current transformers in Saudi Arabia scale heavy primary currents to 1 A or 5 A for meters and protection relays in SEC, Aramco and plant switchgear. This page covers CT types, ratio, class and burden, IEC 61869-2, SEC and Aramco approval, SABER, heat and dust effects, and what drives price and lead time.
0 suppliers found
Skip the search. Post your requirement and we'll connect you with verified current transformers suppliers who quote for your order directly.
Tell us about current transformers in Saudi Arabia and receive competitive quotes from verified suppliers — free, fast, and no obligation.
How step-up and step-down transformers differ, where each is used at Gulf power plants, solar sites and buildings, and what isolation, auto, K-rated, earthing and instrument transformers do.
How to select a current transformer: ratio, metering and protection accuracy classes, burden, knee point, core balance CTs for earth fault, construction types and SEC requirements.
A current transformer (CT) scales a heavy primary current down to 1 A or 5 A so that meters and protection relays can measure it. In Saudi Arabia CTs are fitted in switchgear for SEC network feeders, Aramco and SABIC plant substations, generator panels, and building main boards. They are part of the transformers family for Saudi Arabia, and they pair with voltage transformers in every metering and protection circuit. The units they watch are covered under power transformers and distribution transformers.
IEC 61869-2, edition 1.0 dated 18 September 2012, covers newly manufactured inductive current transformers for measuring instruments and protective devices from 15 Hz to 100 Hz, so it applies directly to the Saudi 60 Hz system. It replaced IEC 60044-1 and IEC 60044-6, which older Saudi specifications may still name.
| Type | Saudi application | Specification focus |
|---|---|---|
| Ring and bar-type CTs | Low-voltage boards, MCCs and generator incomers | Ratio, class, VA burden, window size |
| Split-core CTs | Energy audits and sub-metering in existing towers and factories | Class, output type, opening size |
| Cast resin MV CTs | 13.8 kV and 33 kV switchgear in plants and utility substations | Insulation level, short-time current, metering and protection cores |
| Outdoor oil or gas-insulated CTs | 132 kV, 230 kV and 380 kV substations | Highest voltage, creepage, number of cores, differential protection cores |
| Zero-sequence CTs | Earth fault detection on cable feeders | Window diameter, relay input |
| Low-power sensors | Digital and compact switchgear | Output signal and relay compatibility |
Hitachi Energy lists current, inductive and capacitive voltage and combined instrument transformers for 25 kV to 800 kV. Socomec supplies split-core CTs paired with DIRIS and COUNTIS meters. The CT feeds meters described on the energy meters and monitoring page and relays that trip circuit breakers in low-voltage switchgear.
Size a CT from its ratio, accuracy class, burden and, for protection, its accuracy limit, then check the thermal and short-time ratings against the fault level. Errors here show up as wrong billing or a relay that fails to trip during a real fault.
Give the supplier the model numbers of the relay and meter. Utility-owned metering points may also fix the class, test points and seal arrangement, so request the metering specification before ordering.
Climate attacks the CT's housing, terminals and creepage rather than the core. Inland summer heat, shamal dust and coastal salt create most field problems.
Saudi CTs are specified to IEC 61869 and accepted by SEC, National Grid SA, Aramco or the project consultant. Instrument transformer makers publish SEC approval status for specific products, so ask for it. As of 2026 we could not confirm whether CTs sit on a SABER regulated list, so ask your clearing agent.
| Requirement | Applies to | Authority or owner |
|---|---|---|
| IEC 61869-2:2012 (edition 1.0) | Inductive current transformers | IEC, via the specification |
| SEC or National Grid SA product approval | CTs for utility feeders and metering points | Saudi Electricity Company, National Grid SA |
| Aramco supplier registration and qualification | Supply to Aramco and its contractors | Saudi Aramco |
| Relay and meter manufacturer data | Burden and knee-point voltage | Relay and meter makers |
| SABER product and shipment certificates | Regulated imports | SASO, through certification bodies |
Aramco states that all suppliers must register and that registration does not guarantee business. For regulated imports SABER issues a product certificate and a shipment certificate valid only for that shipment. See our SASO and SABER guide for industrial equipment.
Buy low-voltage CTs from electrical distributors who hold stock and can give a class and burden datasheet. Buy medium and high-voltage CTs through the switchgear builder or directly from the instrument transformer maker, with approvals confirmed for your network.
Ask for routine test certificates for each CT, ratio and polarity marking, the core wiring diagram and approval evidence. Our sourcing guide covers vetting. To compare offers, post your requirement with ratio, class, burden, voltage level and quantity.
Price follows voltage level, cores, accuracy class and short-time rating. Low-voltage CTs are catalogue items. High-voltage CTs are engineered per project.