Metering and custody transfer systems in Saudi Arabia are the measurement skids, provers and flow computers that record oil, gas and product volumes where ownership or allocation changes along the Kingdom's pipelines and terminals. This page explains how to specify a system, which meter suits each fluid, how traceability and proving work, the SASO and Aramco rules as of 2026, and what drives price and delivery.
0 suppliers found
Skip the search. Post your requirement and we'll connect you with verified metering & custody transfer systems suppliers who quote for your order directly.
Tell us about metering & custody transfer systems in Saudi Arabia and receive competitive quotes from verified suppliers — free, fast, and no obligation.
A custody transfer system measures fluid at a transfer point so that the volume or mass can be invoiced or allocated. In Saudi Arabia these points sit at terminals, pump stations and plant boundaries described under compression and pumping stations in Saudi Arabia, next to booster pumps and gas compressors. Because the reading sets a payment, buyers specify the whole system, not just the meter.
A good specification covers six items: the fluid and its range of conditions, the meter technology, the number of runs, the proving method, the flow computer and the analysis needed to correct readings. For the wider instrument range see flow measurement, ultrasonic flow meters, Coriolis flow meters and turbine flow meters.
| Fluid | Common meter | Reference standards |
|---|---|---|
| Sales gas | Multipath ultrasonic; turbine; orifice on older lines | ISO 17089-1, AGA 9 and 7, ISO 5167 |
| Crude oil | Ultrasonic, turbine or Coriolis with a prover | API MPMS Chapter 5, OIML R 117-1 |
| Refined products and LPG | Turbine, positive displacement or Coriolis | API MPMS Chapter 5, OIML R 117-1 |
| Small gas lines and CNG or LNG | Coriolis | AGA 11 |
The meter list follows a 2012 industry review; later editions have changed, so confirm the current editions with the operator.
Write the specification around the uncertainty you need and the evidence you will accept. Start with the commercial requirement, then work back to equipment.
A KROHNE crude oil system example shows a typical scope: a multipath ultrasonic meter, a Coriolis meter on a sample line, automatic sampling, a flow computer with SCADA interface, and a mobile prover with a water draw system. The supplier describes supplying design, construction, calibration, commissioning and testing.
OIML R 117-1:2019 classes liquid measuring systems on pipelines at 0.3, and ship loading systems at 0.5. The maximum permissible error for a class 0.3 complete system is 0.3 percent, and for the meter alone 0.2 percent. The recommendation applies to systems under legal metrology control and does not cover water, which sits under other OIML documents. ISO 17089-1:2019 sets two accuracy classes for ultrasonic gas meters used in custody transfer and allocation; ISO shows it at the stage where a revision is planned.
These are reference points. Operators and contracts often add stricter terms, so request an overall uncertainty calculation from every bidder.
Traceability links your meter calibration to the SI units through a national or accredited laboratory. The SASO National Measurement and Calibration Center maintains national measurement standards, ensures metrological traceability to the SI, and provides calibration for government and private entities and GCC members. SASO's executive regulations under the Measurement and Calibration Law include technical requirements for fuel pumps, weighing instruments, electric energy meters and water meters; the page does not list custody transfer skids. Ask the operator which laboratory certificates it accepts.
A good factory acceptance test proves the whole system, not only the meters. Check the flow computer configuration against the datasheet, run a simulated flow and alarm test, confirm the proving sequence works end to end, and review the calibration certificates of each meter and transmitter. Both commercial parties should witness the test, because a dispute after start-up is harder to settle than a punch list at the factory.
Electronics and sample systems suffer most. Shelters need cooling rated for desert summer peaks, sample lines need insulation or heat tracing to keep the sample representative, and enclosures need protection from blown sand. Remote terminals need redundancy in power and communications because a metering outage stops invoicing.
Registration with the operator and product conformity both matter. The table shows what we verified as of 2026; confirm details with each authority.
| Requirement | Applies to | Authority |
|---|---|---|
| Supplier registration through the e-Marketplace platform, with assessment of financial and technical acceptability | Selling metering equipment to Aramco | Saudi Aramco |
| In-Kingdom Total Value Add (iktva) | Local content for Aramco supply chain participation | Saudi Aramco |
| National measurement standards, traceability and calibration | Calibration certificates for meters and provers | SASO National Measurement and Calibration Center |
| Product conformity through SABER | Imported electrical and measuring equipment | SASO, see the SASO and SABER guide |
| OIML R 117-1:2019 and ISO 17089-1:2019 | Technical reference when named in the specification | OIML, ISO |
Suppliers are global instrument makers and skid fabricators, many with Saudi offices. KROHNE lists custody transfer metering systems for crude oil, Emerson lists gas and liquid metering with provers and supervisory control, and General Valve lists diverter valves used in meter proving. Compare vendors on local calibration support, spares and commissioning staff. Valves for the skid are covered under pipeline valves. To collect quotes, post your requirement.
Streams, size, meter type, prover type, analysers and certification set the cost. Delivery follows meter lead time, flow calibration slots, skid build and testing, then shipping. Local fabrication and iktva score can influence award for Aramco work. Ask for a programme that shows each step and for a clear statement of what the factory acceptance test includes.