CT scanners in Saudi Arabia are the computed tomography systems bought by Ministry of Health and other government hospitals, private hospital groups and imaging centres for trauma, stroke, cardiac and cancer imaging. This page lists Saudi suppliers and explains SFDA class C marketing authorisation, NRRC radiation practice licensing and Saudi technical provisions as of 2026, how to specify the scanner, and what shapes price and delivery.
0 suppliers found
Skip the search. Post your requirement and we'll connect you with verified ct scanners suppliers who quote for your order directly.
Tell us about ct scanners in Saudi Arabia and receive competitive quotes from verified suppliers — free, fast, and no obligation.
A CT scanner acquires X-ray projections from a rotating gantry and reconstructs them into cross sectional and 3D images of the head and body in seconds. Among the modalities in diagnostic equipment for Saudi hospitals it carries the heaviest regulatory load, because it is both a class C medical device under SFDA rules and a radiation practice licensed by NRRC.
| Scanner type | Where it fits in Saudi Arabia | What decides the choice |
|---|---|---|
| General multislice CT | Regional and general hospitals, private polyclinics, second scanner in larger hospitals | Coverage, rotation speed, tube heat capacity, reconstruction software |
| Cardiac capable wide coverage CT | Cardiac centres and tertiary hospitals in Riyadh, Jeddah, Dammam and Madinah | Temporal resolution, coverage, ECG gating, heart rate tolerance |
| Spectral or dual energy CT | Oncology, vascular and emergency services | Spectral method, routine use in workflow, post processing licences |
| Large bore CT simulator | Radiotherapy departments and oncology centres | Bore diameter, flat couch, external laser system, planning software link |
| Mobile or relocatable CT | Temporary capacity, field hospitals and seasonal demand | Trailer or container build, power and cooling on site, licensing of the location |
Most CT projects come with other imaging. Hospitals typically tender MRI systems for hospitals, X-ray and fluoroscopy equipment and ultrasound systems in the same package, and emergency departments add patient monitors for transfers to the scanner.
As of 2026 a CT scanner needs an SFDA Medical Device Marketing Authorization (MDMA) as a class C device, and the hospital needs an NRRC radiation practice licence. The SFDA National Provisions add Saudi specific technical conditions on power supply, climate and dose recording that should be written into the specification.
| Requirement | Applies to | Authority or source |
|---|---|---|
| MDMA through the GHAD system, by the manufacturer or its licensed Saudi authorised representative | Each CT model and configuration supplied in the Kingdom | SFDA, MDS-REQ 1 version 6.0 |
| Class C under Rule 10 (ionising radiation for diagnostic radiology) | CT scanners and devices that control them | SFDA, MDS-REQ 1 |
| 60 Hz design at 230 V or 400 V nominal | Mains powered medical devices | SFDA National Provisions, Article Seven |
| Stated performance under local temperature and humidity, shown in the IFU and label | All medical devices | SFDA National Provisions, Article Thirteen |
| Automatic recording of dose, protocol and patient age, gender and weight in standardised formats | Imaging medical devices | SFDA National Provisions, Article Fifteen |
| Radiation practice licence via the Amaan platform | Facilities operating CT | NRRC |
| IEC 60601-2-44 | Basic safety and essential performance of CT scanners | IEC, in the manufacturer's technical file |
MDS-REQ 1 also sets essential principles for devices emitting ionising radiation: the user must be able to control emissions, unintended and scattered exposure must be reduced as far as possible, and diagnostic devices must reach the image quality needed at the lowest practical exposure. In practice that means the bid should list the dose reduction tools and how dose is exported, so the hospital can meet Article Fifteen. The National Provisions copy we checked is version 2.0 from 2018; confirm the current text with SFDA.
Specify for throughput, uptime and the site. Saudi emergency departments and trauma centres scan around the clock, and a scanner that is down waiting for a tube from abroad pushes patients to another hospital.
Government hospitals buy CT mainly through NUPCO tenders, where suppliers must be registered and qualified before buying the tender document; private groups negotiate directly with the manufacturer's Saudi office or its authorised distributor. Either way, the bidder should hold or work with the MDMA holder and support the NRRC file.
Ask every bidder for: the MDMA number and authorised representative; written 60 Hz confirmation; how dose and patient data are recorded and exported; which shielding, acceptance test and quality control documents it supplies for NRRC; the number of CT engineers in Riyadh, Jeddah and Dammam; tube cover; software upgrade rights; and the model's end of service date. Our supplier sourcing guide explains supplier checks and RFQs. To compare offers, post your requirement with the case mix and site details.
Detector coverage, spectral capability, software licences and the service term set the price, and a full risk contract with tube cover can rival the equipment price over its life. Compare total cost over the same term.
Lead time includes the MDMA if the configuration is new to the Kingdom, the factory slot, sea freight into Jeddah Islamic Port or King Abdulaziz Port in Dammam, SFDA clearance, installation, acceptance testing and the NRRC licence. SFDA import rules restrict used devices to listed cases, so check before considering a refurbished scanner.