X-ray equipment in Saudi Arabia means digital radiography rooms, mobile units, C-arms, fluoroscopy and angiography systems for government and private hospitals and imaging centres. This page lists Saudi suppliers and explains the NRRC radiation practice licence and its 2026 quality control regulation, SFDA marketing authorisation and 60 Hz and dose recording rules, NUPCO tenders, and what sets price and delivery.
0 suppliers found
Skip the search. Post your requirement and we'll connect you with verified x-ray equipment suppliers who quote for your order directly.
Tell us about x-ray equipment in Saudi Arabia and receive competitive quotes from verified suppliers — free, fast, and no obligation.
In Saudi Arabia, X-ray equipment covers digital radiography rooms, mobile X-ray carts, theatre C-arms and fluoroscopy or angiography systems bought by Ministry of Health hospitals, other government health providers, private hospital groups and primary care networks. It sits inside the Saudi diagnostic equipment family, which deals with cooling, power and NUPCO buying across all modalities. Here the focus narrows to radiography: what to write in the specification, and what the SFDA and the Nuclear and Radiological Regulatory Commission (NRRC) require from the device and the facility.
Flat panel digital radiography is now the default in Saudi tenders. Older computed radiography rooms are being upgraded with detector retrofit kits, which are cheaper than a new room but still bring an NRRC quality control obligation once the system changes.
| System | Typical Saudi setting | Points to pin down |
|---|---|---|
| Fixed DR room, ceiling or floor mounted | Hospital radiology, emergency, specialist and private outpatient centres | Generator power, tube, detector count and size, auto-positioning, table load, 60 Hz build |
| Mobile radiography unit | ICU, wards, isolation and emergency areas | Motorised drive, battery capacity, detector sharing with the fixed room, cleanable surfaces |
| C-arm | Orthopaedic, spine, vascular and urology theatres | Detector type and size, pulsed mode, dose display, compatibility with radiolucent operating tables |
| R/F fluoroscopy room | Contrast studies, urology, paediatric swallow studies | Remote control table, pulse rates, dose area product recording |
| Angiography system | Cardiac and neuro cath labs, hybrid theatres | Plane count, detector size, room integration, UPS for the whole chain |
| Bone densitometry (DXA) | Osteoporosis clinics and women's health centres | Scan modes, reference database, NRRC QC tests for densitometry |
Neighbouring purchases are listed separately: CT scanners for Saudi hospitals, MRI systems for radiation-free cross-sectional imaging, and dental X-ray units for clinics. Food factory checkweighing machines with X-ray heads appear under X-ray inspection systems, and pipe weld radiography under non-destructive testing; neither is medical equipment.
As of 2026 an X-ray system in Saudi Arabia needs SFDA marketing authorisation (MDMA) as a medical device, a radiation practice licence for the facility from the NRRC, and a quality control programme that tests the unit before it is used on patients. SFDA's National Provisions add Saudi-specific technical conditions on top of the marketing authorisation, which is explained on the Saudi healthcare and medical equipment sector page.
| Requirement | Effect on the purchase | Authority |
|---|---|---|
| Radiation practice licence, applied for on the Amaan platform, 30 working days once the file is complete | The hospital or centre must hold it; documents follow NRRC technical regulations and guidance | NRRC |
| Radiation Safety Regulation NRRC-R-01 (Rev. 0.1) | Framework for radiation protection, including medical exposures | NRRC |
| NRRC-R-01-SR03 Rev. 1 (approved June 2026), QC programme for medical radiological equipment | QC tests at commissioning and relocation, after major repairs or software changes, and annual reporting | NRRC |
| National Provisions, Article Seven | Mains devices designed for a 60 Hz supply at 230 V or 400 V nominal, SASO-2203 plug where relevant | SFDA |
| National Provisions, Article Fifteen | Imaging devices must automatically record dose, protocol data and patient age, gender and weight in standardised formats | SFDA |
| National Provisions, Articles Twelve and Thirteen | Service manuals available in English and, on request, Arabic; performance under Saudi temperature and humidity stated in the IFU | SFDA |
| IEC 60601-2-54:2022 | Safety of radiography and radioscopy equipment, with IEC 60601-2-43 for interventional systems | IEC, via the maker's test reports |
NRRC-R-01-SR03 makes the facility's authorised person responsible for QC tests before first clinical use, after relocation, after major maintenance or upgrades, and after any software change that could affect patient safety. For diagnostic and interventional radiology the tests are run by, or with the documented advice of, a medical physicist, and only recognised and competent service providers may perform them. For general radiography its appendix lists tests such as tube leakage at acceptance, and kV accuracy, half value layer, exposure time, output linearity and automatic exposure control checks at acceptance and annually. An annual QC report goes to the NRRC within three months of the tests. Put the acceptance test scope, test phantoms and calibrated instruments in the supplier's contract, and ask for the manufacturer tolerance limits that the regulation compares results against.
Hot, dusty air in Riyadh and the central region and humid coastal air in Jeddah and Dammam both end up in the X-ray room if the air conditioning and filtration are undersized. SFDA Article Thirteen obliges the manufacturer to state how the device copes with local temperature and humidity, so read those limits in the IFU and design the room to them. Specify filters on the air handling units that cope with dust events, keep generator cabinets out of unconditioned corridors, and give mobile units a cool charging bay. For angiography, plan a UPS that carries the full imaging chain, not just the console.
Government hospitals buy mainly through NUPCO tenders, and private groups buy direct from the manufacturer's Saudi office or its authorised distributor. NUPCO suppliers must be registered and qualified before buying a tender document, detailed device specifications are only inside that document, samples may be requested within three days, and awards can be split among several suppliers. NUPCO quotes three to six months from start of evaluation to preliminary award.
SFDA import requirements (MDS-REQ5) prohibit used medical devices except listed cases such as return after repair or calibration, so check with SFDA before considering a refurbished room. The supplier sourcing guide for Saudi Arabia and the UAE explains verification and fair comparison. To reach several suppliers, post your requirement with the room type, detector count and city.
Configuration and service term drive price, while NRRC licensing and room works drive the timeline. Detector count, generator rating, auto-positioning and dose software separate a basic room from a premium one; shielding, electrical works and acceptance QC are often priced separately and should be visible in every offer.
Mobile units in Saudi stock can be delivered in weeks. Fixed rooms and C-arms usually take a few months once factory production, sea freight into Jeddah Islamic Port or King Abdulaziz Port in Dammam, SFDA port clearance, the NRRC licence and acceptance testing are counted. NUPCO evaluation adds its own months for government buyers.