Soft starters in Saudi Arabia are electronic starters that limit starting current and torque for AC motors on pumps, fans, compressors and conveyors, and they enter the Kingdom as electrical products under SASO conformity rules. This page explains when to choose one over a drive, sizing for Saudi heat, IEC 60947-4-2, SABER as of 2026, and the makers.
0 suppliers found
Skip the search. Post your requirement and we'll connect you with verified soft starters suppliers who quote for your order directly.
Tell us about soft starters in Saudi Arabia and receive competitive quotes from verified suppliers — free, fast, and no obligation.
Saudi plants choose a soft starter when a motor runs at fixed speed and the supply, pipework or coupling needs protection from the shock of a direct start. Typical duties are water transmission and booster pumps, cooling tower fans, compressors and conveyors. The starter belongs to the motors and drives family for Saudi projects.
| Duty | Why a soft starter fits | When to look at a drive instead |
|---|---|---|
| Large water pumps | Soft stop reduces surge and water hammer | Flow must vary with demand |
| Fans and blowers | Limits belt and coupling stress | Airflow control saves energy |
| Compressors | Lower inrush on weak or generator-fed supplies | Load follows demand |
| Conveyors and crushers | Smooth torque build up | Speed changes are needed |
For speed control, compare variable frequency drives. Soft starters drive standard AC induction motors, and starters for hazardous-area duties must be separated from the motors described under explosion proof motors. They are built into motor control centers with short-circuit protection from circuit protection devices and switching parts from relays and contactors.
Size a soft starter from the motor current, the load's starting torque, the number of starts per hour and the panel temperature. The motor kW alone is not enough.
WEG's SSW900 guide defines its standard duty as 3 times full-load current for 30 seconds, with 10 starts per hour for some frames, 3 per hour for others, and 5 per hour for the largest. Danfoss's MCD 600 covers 200 to 525 VAC and 380 to 690 VAC supplies at 50 or 60 Hz with plus or minus 5 percent tolerance, in frames from 20 A to 1,250 A. Rockwell Automation supplies soft starters within a wider low and medium voltage motor control range.
Soft starters are rated at a reference ambient, commonly 40 °C, and lose current capacity above it, so panels in Eastern Province plants and outdoor kiosks need the derated figure. Sand and dust attack ventilation openings more than the thyristors.
ABB's note for PSR, PSE and PSTX starters gives derating of 0.8 percent per degree above 40 °C for PSR and PSTX and 0.6 percent for PSE, and an altitude formula for sites between 1,000 and 4,000 m. WEG's SSW900 guide states 55 °C without derating for models up to 412 A and 40 °C for 480 A and above, with 2 percent derating per degree beyond that, and 1 percent per 100 m above 1,000 m.
For high-altitude plants in the Kingdom, apply the maker's altitude derating on top of temperature derating.
WEG advises against direct sun, rain, excess moisture, dust, metallic particles and oil mist, and marine environments. In Jubail, Yanbu and Jeddah, specify enclosed panels with filtered ventilation or air conditioning and schedule filter cleaning.
Soft starters are designed to IEC 60947-4-2 and, as electrical products, are handled by SASO's conformity system through SABER. Checked as of 2026; ask a certification body whether your starter's code needs a certificate.
| Requirement | Applies to | Authority |
|---|---|---|
| IEC 60947-4-2 | AC semiconductor motor controllers and starters up to 1,000 V AC; EN 60947-4-2:2012 was withdrawn on 11 January 2026 in favour of EN IEC 60947-4-2:2023 | IEC and CENELEC, called up by project specifications |
| BD-142004-01 electrical safety and EMC | Electrical and electronic products on the regulation's list; IEC CB report and certificate is one accepted route | SASO, through approved certification bodies |
| SABER PCoC and SCoC | Product and shipment certificates requested by the importer before shipping | SASO |
| Owner and utility specifications | Approved manufacturers, coordination tables and local service on Aramco, SEC and water projects | The owner |
Intertek says SABER was extended to electrical products on 1 April 2019, and that its conformity approach for BD-142004-01 rests on an IEC CB scheme report, a GCC notified body report or an ISO/IEC 17025 report. Its table does not name soft starters, so confirm with a certification body. See the guide to SASO and SABER certificates for industrial equipment.
Protection coordination also matters: WEG advises ultra-fast aR fuses and an AC-3 contactor ahead of the SSW900, and reminds users that fuses must be rechecked if the start time or starts per hour change.
Commissioning a soft starter means setting the start profile for the real load, confirming the protection settings and recording them. These checks are good practice to compare with the maker's manual, not extra regulations.
Soft starters are available from manufacturer entities, electrical distributors and panel shops in Riyadh, Jeddah and Dammam.
Ask for stock status in the Kingdom, a local commissioning engineer and the approved vendor list if the project is for an owner. The sourcing guide for Saudi Arabia and the UAE explains how to verify authorisation.
Price depends on current rating, voltage, bypass type and communication options, and lead time on local stock and the SABER certificate position.
To compare quotes, post your requirement with motor current, voltage, load type, start time, starts per hour, ambient and network.