Dissolved air flotation, or DAF, floats oils, fats and fine solids to the surface of a tank using micro-bubbles so they can be skimmed away. In Saudi Arabia it is used for poultry, food, petrochemical and municipal effluent, and as pretreatment. This page covers how it works, discharge rules, sizing questions and supplier checks.
0 suppliers found
Skip the search. Post your requirement and we'll connect you with verified dissolved air flotation suppliers who quote for your order directly.
Tell us about dissolved air flotation in Saudi Arabia and receive competitive quotes from verified suppliers — free, fast, and no obligation.
A dissolved air flotation system saturates water with air under pressure, releases it into a flotation tank, and lets the resulting micro-bubbles carry oil, grease and fine solids to the surface where a skimmer removes them. It is a pretreatment or primary stage in wastewater treatment in Saudi Arabia, and it is different from the flotation cells used to separate minerals in mining.
A reference page describes the stages as presaturation at roughly 3 to 6 atmospheres, bubble formation as pressure drops, with bubbles typically 30 to 50 micrometres across, flotation of the particles to the surface and discharge of clarified water from the bottom. Operators have to maintain a suitable air-to-solids ratio, and coagulants and flocculants are normally added first.
| Configuration | Where it suits in the Kingdom | What to ask |
|---|---|---|
| Packaged skid-mounted DAF | Poultry and food plants, industrial city factories, camps | Flow range, footprint, skimmer type, chemical dosing included or not |
| Recycle-flow DAF | Most industrial effluent with variable solids | Recycle ratio, saturation vessel, air supply |
| Large tank with scrapers | Municipal and large industrial works, pretreatment for membranes | Surface loading, retention time, sludge removal |
| DAF plus biological stage | Slaughter, dairy and poultry effluent | Link to aeration systems and membrane bioreactors |
DAF is used in the Kingdom wherever wastewater carries fats, oils or light solids, notably food and poultry processing, dairy, slaughter, petrochemical and oil and gas streams, laundries and some municipal plants. A published Saudi example is a new membrane bioreactor effluent plant for a poultry processor, treating roughly 6,000 cubic metres a day of poultry and rendering wastewater, where aerated and mixed balance tanks feed a DAF stage and the DAF sludge goes through a holding tank to a tricanter centrifuge. The plant is remote and runs at ambient temperatures above 40 degrees Celsius, according to the article.
The reference page on DAF lists municipal primary treatment, food and beverage, pulp and paper, produced water and membrane pretreatment as applications, and says DAF can remove over 90 percent of suspended solids and fats, oils and grease. It does not source that figure, so treat it as an upper-end claim and require performance guarantees on your effluent.
Upstream, a grease trap or interceptor handles coarse fat; downstream, floated sludge goes to sludge dewatering equipment, and the whole flowsheet sits within industrial effluent treatment.
DAF is process equipment, so the rules that matter are the discharge permit and monitoring obligations on the treated water. As of 2026, the National Center for Environmental Compliance (NCEC) issues permits under the Implementing Regulation of the Environmental Law for the Protection of Aquatic Environments from Pollution.
Sewer-connected industrial users in industrial cities may also face the operator's own limits, so ask the city authority for its acceptance conditions. Imported electrical items may need SASO or SABER certificates; see the guide on SASO and SABER certificates.
A DAF plant needs coagulant and flocculant dosing, pH control, an air supply and a plan for float sludge, and it needs enough instrumentation to keep dosing in step with the feed. Jar tests on your wastewater decide the chemistry.
Warm feed holds less dissolved air and keeps fats emulsified, so summer duty can need more air capacity or pre-cooling, and remote sites need spare parts on hand. Ask the designer for the design temperature and the air capacity at that temperature; that is general process behaviour, not a figure from a Saudi source. Desert dust and sun call for covered electrical panels, shaded pumps and corrosion-resistant materials for saline or aggressive effluent.
Choose a supplier that designs from your effluent analysis, offers a pilot or jar test, guarantees outlet quality and keeps spares and engineers in the Kingdom. Ask:
Xylem describes itself as a designer and manufacturer of DAF systems, and its Flygt listing shows its pump and mixer range. Sulzer lists flotation of oil and grease among the uses of its submersible aerators. The sourcing guide covers how to check authorised dealers.
Price follows flow, effluent strength, tank and skimmer design, saturation system, chemical dosing and controls, and running cost is driven by chemicals, power and sludge disposal. Lead time depends on whether the unit is packaged or site-built, plus shipping and customs. Ask for a written schedule that includes commissioning and operator training. To compare offers, post your requirement with flow and effluent data.