Lighting in Saudi Arabia covers industrial LED luminaires, floodlights and high bays, street and area lighting, emergency lighting and explosion proof fittings for oil, gas and chemical sites. This page lists Saudi lighting suppliers and explains how heat and sandstorms affect LEDs, which SASO energy efficiency, SABER, SASOEX and Civil Defense requirements apply, and what drives price and delivery.
0 suppliers found · 5 subcategories
Skip the search. Post your requirement and we'll connect you with verified lighting suppliers who quote for your order directly.
Tell us about lighting in Saudi Arabia and receive competitive quotes from verified suppliers — free, fast, and no obligation.
In Saudi Arabia, lighting for industrial, infrastructure and commercial projects covers LED luminaires for plants and warehouses, floodlights and high bays, road and area lighting, emergency lighting and explosion proof fittings for hydrocarbon areas. It is listed under electrical equipment in Saudi Arabia. Volumes are driven by industrial cities, logistics zones, road networks, stadium and entertainment projects and the giga-projects, all now specified with LED.
| Lighting type | Where it is used in Saudi Arabia | What to specify |
|---|---|---|
| Industrial LED luminaires | Manufacturing in Jubail, Yanbu, Sudair and Riyadh industrial cities, workshops, cold stores | Lumens and efficacy, glare, rated ambient, driver life, IP and IK rating, SASO energy label |
| Floodlights and high bays | Warehouses, port and logistics yards, stadiums, plant areas | Optics, mounting height, surge rating, aiming and glare control |
| Street and area lights for roads and communities | Highways, municipal roads, residential communities, car parks | Road class, distribution, controls, pole and bracket, coating for coastal sites |
| Emergency lighting | Escape routes in buildings, plant rooms, tunnels | Duration, central or self-contained supply, self-test, Civil Defense acceptance |
| Explosion proof luminaires for oil, gas and chemical sites | Aramco and SABIC facilities, terminals, fuel stations | Zone, gas group, temperature class, IECEx based SASOEX certificate |
Pick Saudi lighting by its performance at site temperature and its resistance to dust, not by catalogue efficacy alone. Interior summers, rooftop and pole positions in full sun, and frequent sandstorms are harder on LED drivers and seals than the test conditions behind a datasheet.
LED life is set mainly by how hot the driver and LED board run. Ask each supplier for the luminaire's maximum rated ambient, the lumen maintenance at that ambient and the driver's rated life. For high bays under uninsulated steel roofs in Riyadh, Qassim or Al Kharj, assume roof-space air hotter than outdoor shade temperature and check the margin.
The IEC 60529 IP code grades dust protection with its first digit: 5 for dust protected, where some dust may enter but not enough to interfere with operation, and 6 for dust-tight. For outdoor and plant lighting in Saudi Arabia, IP66 is a common minimum because it is dust-tight and withstands powerful water jets used for cleaning. Plan lens cleaning after dust events, since a dusty lens loses light even when the housing is sealed.
Along the Gulf coast at Dammam, Jubail and Ras Tanura and on the Red Sea at Jeddah, Yanbu and the coastal giga-projects, use corrosion-resistant coatings, stainless fasteners and UV stable lenses, and ask for salt spray test evidence on street and floodlight housings.
On long Saudi road networks, logistics parks and remote plants, the cost of sending a crew and a lift to replace a failed fitting can exceed the fitting itself. That favours luminaires with replaceable drivers, surge protection matched to long outdoor cable runs, and controls that report failures. For emergency lighting across large estates, central monitoring or self-test luminaires reduce the manual testing load and give the facility team a record for Civil Defense inspections. Ask suppliers which spare parts are held in the Kingdom and for how many years.
As of 2026, lighting products sold in Saudi Arabia must meet SASO energy efficiency, functionality and labelling standards and be certified through SABER, hazardous-area luminaires need a SASOEX certificate, and emergency lighting must satisfy the Saudi Fire Code and Civil Defense. Owners such as Aramco add their own hazardous-area and material requirements.
| Requirement | Applies to | Authority |
|---|---|---|
| SASO 2870 energy efficiency, functionality and labelling | Lamps and lighting products within its scope | SASO |
| SASO 2902 (Part 2) | Lighting products not covered by SASO 2870 | SASO |
| SABER product and shipment certificates | Imported regulated lighting products | SASO through the SABER platform |
| SASOEX certificate based on IECEx or ATEX evidence | Luminaires for potentially explosive atmospheres | SASO |
| Fire code and civil defence acceptance | Emergency and exit lighting in buildings | Saudi Fire Code SBC 801 and the General Directorate of Civil Defense |
| Owner specifications | Lighting in Aramco, SABIC and other plants | Owner engineering standards and vendor approval |
Intertek reported that SASO 2870/2018 replaced the 2015 edition with a new energy label template, and that SASO 2902/2018 covers lighting products outside SASO 2870, with enforcement from 7 December 2018. These standards are revised from time to time, so confirm the current edition and label before shipping. SASO's own certificate page states that the SASOEX certificate is issued on the basis of an IECEx or ATEX test certificate and report, and asks for the IECEx certificate of conformity, test report and quality assessment report. For the wider SABER process, read the guide to SASO and SABER certificates.
Saudi consultants often design emergency lighting to British and European references alongside SBC 801. NICEIC reports that BS 5266-1 was revised with effect from 31 October 2025, with the 1 lux escape route minimum now applying across the floor width, power supplies sized for LED power factor and inrush, and photometric checks at least every five years. It is used together with BS EN 50172:2024 and BS EN 1838:2024.
Saudi lighting is supplied through brand offices in Riyadh, Jeddah and Dammam, authorised distributors and lighting contractors, with local assembly of some ranges. For industrial and outdoor projects, the realistic shortlist depends on SASO certificates and application experience.
A brand office or authorised distributor gives you lighting calculations, a Saudi warranty and certificates that match the model. Stockists suit maintenance replacements, but check the SASO energy label and SABER registration on the product. Coordinate lighting with the power and fire resistant cables for lighting circuits, the lighting panels and boards and breakers selected for LED inrush.
The quality of the driver, the housing and the certification set most of an LED luminaire's price in Saudi Arabia; the LED chips are a smaller share.
Common luminaires are stocked by Saudi distributors; large project volumes, sports and road lighting and Ex fittings are usually made to order. To compare offers fairly, post your requirement with the lighting design and certification needs.
Which industrial products need a MoIAT certificate, how ECAS differs from the Emirates Quality Mark, and how to check a supplier certificate before you buy.