Float level switches use a buoyant float to operate a contact at a set liquid height, and in Saudi Arabia they control pumps and raise alarms in sumps, water tanks, cooling basins, wastewater plants and fuel tanks. This page covers the types, the density and fouling limits, SASOEX and SABER points as of 2026, the brand available and what drives price and delivery.
0 suppliers found
Skip the search. Post your requirement and we'll connect you with verified float level switches suppliers who quote for your order directly.
Tell us about float level switches in Saudi Arabia and receive competitive quotes from verified suppliers — free, fast, and no obligation.
A float level switch has a float that rises and falls with the liquid surface, and at a fixed position it operates a switch that starts a pump, sounds an alarm or trips a process. Endress+Hauser describes the principle as the float's position being detected by a sensor to trigger the switching operation, and lists its Liquifloat FTS20 for point level detection in liquids, as a pump protector or level alarm, in open basins such as sewage treatment plants and in tanks. In level measurement across Saudi Arabia floats are everywhere: water towers and ground tanks, sewage lift stations, cooling tower basins, fire water tanks, and generator and diesel day tanks.
| Type | Typical Saudi use | Key specification points |
|---|---|---|
| Cable float switch | Sewage lift stations, drainage sumps, water tank pumps | Cable material and length, float shape, IP68 rating, weight |
| Side-mounted float switch | Tanks with alarm nozzles, bunds and day tanks | Thread or flange, density rating, contact type |
| Rod float switch with several points | Water and fuel tanks needing low, high and high-high levels | Stem length, number of reed points, wetted materials |
| Hazardous-area float switch | Fuel, solvent and petrochemical tanks | NAMUR or intrinsically safe output, zone, certificate |
| Lever or mechanical float | Cooling tower make-up and simple tanks | Linkage, connection, temperature rating |
The Liquifloat FTS20 offers two outputs: a NAMUR signal for hazardous areas, noted to Zone 1, or an AC/DC change-over contact for general use. Endress+Hauser does not state limits such as temperature or float materials on that page, so read the technical documentation before selecting.
A float switch stops working when the float cannot move, when it is not buoyant enough, or when the contact is overloaded. Check each of those against the site before you order.
When the operator needs a continuous reading instead, specify a radar level transmitter, or ultrasonic level sensors for clean water. For sticky or coating products, capacitance level probes are often a better choice, and a pressure transmitter gives a hydrostatic reading in water. Floats stay preferred for independent high-high alarms and for simple, low-cost pump cut-out.
Work from the tank or sump drawing: the lowest float protects the pump from running dry, the start and stop floats set the pump cycle, and the high alarm sits below the overflow with room for the pumps to catch up. Fit a separate high-high float on its own circuit for an independent alarm so that one failure cannot hide an overflow. Record the heights on the commissioning sheet, test each float at handover by lifting it by hand or raising the level, and put the test on the maintenance schedule, because floats in wastewater foul silently between visits.
Saudi summer temperatures, dust and salt act on cables, housings and liquids rather than on the float principle. Water in rooftop and ground tanks in Riyadh and Jeddah gets very warm, so check the cable and float temperature rating and the buoyancy margin. Dust and sand collect in sumps and around floats on construction sites, so use guarded floats. In coastal Jubail, Yanbu and Dammam, salt attacks junction boxes and carbon steel, which makes 316 stainless steel or polymer floats and sealed, rated housings the sensible specification. Condensation inside a junction box damages reed contacts and terminals over time.
As of 2026, float switches in Saudi Arabia need SASOEX certification in explosive atmospheres and SABER certificates where a SASO technical regulation applies, with potable water materials and project or Aramco specifications as further conditions. Confirm each point with the authority and the owner before ordering.
| Requirement | Applies to | Authority |
|---|---|---|
| SASOEX certificate | Switches in fuel, solvent and chemical tanks and other classified areas | SASO |
| SABER product and shipment certificates | Imports under a SASO technical regulation | SASO |
| Intrinsically safe or NAMUR circuit | Hazardous-area switches connected to a barrier | Certificate and system documents |
| Potable water material suitability | Switches in drinking water tanks | Water utility and project specification |
| Independent overfill alarm | Petroleum storage tanks | Aramco or terminal operator, API Standard 2350 practice |
The SASO and SABER guide explains who may request the certificates, and the storage tanks and terminals page covers terminal alarms. Read each certificate against the exact model quoted.
Float switches reach Saudi buyers from manufacturers' regional offices, authorised distributors, electrical wholesalers and pump suppliers in Riyadh, Jeddah, Dammam and Jubail. Endress+Hauser makes the Liquifloat float switch. Questions to ask each bidder:
The sourcing guide covers authorisation and registration checks, and you can post your requirement to compare quotes.
Float and cable materials, switch points, hazardous-area certification, cable length and pressure rating set the price. Standard cable floats for sumps are common distributor stock, whereas multi-point stainless rod switches and SASOEX-certified models are factory orders. Allow time for SABER clearance and port handling at Jeddah Islamic Port or King Abdulaziz Port in Dammam. Standardising on one model across pump stations and holding a few spares shortens repairs.