Fire rated doors in Saudi Arabia, called fire resistant doors in SASO's regulation, are tested steel, timber and glazed doorsets that stop fire and smoke spreading between compartments. This page covers the types and rating codes, the SASO Type 3 conformity certificate on SABER, fire testing that Saudi Civil Defense accepts against SBC 201 and SBC 801, site checks, the brands supplied, and what drives price and lead time.
0 suppliers found
Skip the search. Post your requirement and we'll connect you with verified fire rated doors suppliers who quote for your order directly.
Tell us about fire rated doors in Saudi Arabia and receive competitive quotes from verified suppliers — free, fast, and no obligation.
Saudi Arabia treats fire doors more strictly than any other door product, and that shapes the buying process. Within doors and windows supplied in Saudi Arabia, fire resistant doors are the one group that needs a Type 3 product conformity certificate under SASO's regulation, rather than the Type 1a route used for ordinary doors and windows, and they need fire testing that Saudi Civil Defense accepts. Buyers include contractors on hospital, school, housing and mall projects, industrial owners in Jubail, Yanbu and Ras Al Khair, and facility managers correcting defects found in civil defence inspections. Checked in October 2026.
Steel doorsets dominate in Saudi industrial plants, stairwells and service areas, timber doorsets serve hotels, housing and offices, and glazed or sliding fire doors cover lobbies and large openings.
| Door type | Where Saudi projects use it | Specification points |
|---|---|---|
| Steel single and double doorsets | Stairwells, plant rooms, substations, plants in Jubail and Yanbu | Rating, frame and anchor type, certified panic hardware |
| Timber fire doorsets | Hotels in Makkah and Madinah, housing, offices, schools | Certified core, permitted finishes, intumescent seals |
| Glazed fire doors and screens | Hospital corridors, mall lobbies, airport areas | Integrity only or insulated glass, pane size limits |
| Fire rated sliding and hinged industrial doors | Warehouses in Riyadh, Jeddah, Dammam and Sudair | Release on alarm, closing speed, certified size range |
| Smoke control doors | Hospital and hotel corridors | Smoke leakage class with the fire rating |
| Blast and fire doors | Oil, gas and petrochemical control and equipment buildings | Combined blast and fire test evidence, operator approval |
Glass panels in these doors come from fire rated glazing suppliers and must match what was tested. Large fire shutters are covered with industrial roller shutters, and ordinary entrance doors such as automatic sliding doors need a separate fire tested version if they sit in a fire wall.
Fire resistant doors in Saudi Arabia need a SASO Type 3 product conformity certificate and a shipment certificate on SABER, plus fire test evidence that Saudi Civil Defense accepts to show compliance with SBC 201 and SBC 801.
| Requirement | Detail | Authority |
|---|---|---|
| Type 3 product conformity certificate and shipment certificate on SABER | Named in SASO's guide for fire resistant doors and other fire resistant openings; regulation in force at ports and factories since 27 June 2021, first amendment June 2023 | SASO and its accepted conformity assessment bodies |
| Fire resistance testing showing compliance with SBC 201 and SBC 801 | Doors, walls and glazed partitions; Intertek reported in 2021 a Civil Defense approved, ISO 17025 accredited fire lab in Al Khobar | Saudi Civil Defense |
| EN 1634-1 with EN 16034, or UL 10C | Test standard named in the specification | CEN, UL |
| ISO 14001 (or equivalent) at the factory, Arabic labelling | General SASO regulation requirements | SASO |
| Aramco or SABIC vendor requirements | Fire and blast doors for owner operated industrial sites | Owner specification |
SASO's guide also says that meeting the regulation does not replace compliance with the Saudi Building Code. Only an importer or local manufacturer with a Saudi commercial registration can hold the certificate, so for imported doors the local distributor normally owns it. Our guide to SASO and SABER certificates walks through the product and shipment certificate steps. Fire doors are part of the wider fire protection scope reviewed by civil defence, so check the certificate scope on SABER and the civil defence requirement for your building before ordering.
The rating shows how long the door resisted fire and which criteria it met, written as letters and minutes on European tests or as minutes on UL tests.
On US designed projects, UL 10C gives a time rating for swinging door assemblies under positive furnace pressure; it does not cover sliding fire doors. Match the criteria on the door to the wall rating in the fire strategy.
A fire door performs only if it is installed and kept as tested. Saudi inspectors find faults mostly at frames, gaps and hardware.
Saudi fire doors come from Saudi factories making certified designs and from international brands imported by local distributors who hold the SASO certificate.
Brands carried include Hörmann fire and smoke doors, Teckentrup steel fire doors, Novoferm fire rated doorsets, ASSA ABLOY, Van Dam blast, fire and offshore steel doors, Metaflex fire rated sliding doors, Neuform fire, acoustic and radiation protection doorsets, Sanwa, Shakti Hormann and Promat fire door cores and boards.
Request the SASO certificate number and scope, the fire test report and the lab's civil defence acceptance, the hardware schedule, tested frame details and warranty. See how to vet suppliers in Saudi Arabia for broader checks, and post your fire resistant door requirement to receive comparable offers.