Control cables in Saudi Arabia are multicore cables that carry control and interlock signals across refineries, utilities and large buildings. This page covers armoured, LSHF, screened and fire resistant types, core count and size, heat and sand effects, IEC 60502-1 and BS standards, SASO, SABER and Fire Code notes as of 2026, linked brands and what drives price and lead time.
0 suppliers found
Skip the search. Post your requirement and we'll connect you with verified control cables suppliers who quote for your order directly.
Tell us about control cables in Saudi Arabia and receive competitive quotes from verified suppliers — free, fast, and no obligation.
Who makes power cable for UAE and Saudi projects, which IEC and BS standards apply, how 50 °C heat changes cable size, and what MoIAT, Civil Defence, SABER and SEC require.
Control cables carry low-level command, interlock and status signals across many numbered cores, and they link motor control centres, PLC panels, valves and field switches. In Saudi Arabia they are bought under the cables and wiring family for Saudi Arabia for refineries and petrochemical plants in Jubail and Yanbu, power and water plants, and large commercial buildings in Riyadh and Jeddah.
| Type | Saudi application | Construction notes |
|---|---|---|
| PVC insulated, steel wire armoured | Plant control between MCC buildings and field equipment | 0.6/1 kV, numbered cores, galvanised steel wire armour, PVC sheath |
| LSHF armoured | Hospitals, airports, towers and enclosed public buildings | BS 6724 style low smoke halogen free sheath |
| Unarmoured multicore | Panels, protected trays and sub-circuits | Numbered cores, lower voltage grades |
| Screened control cable | Variable speed drives and PLC I/O in noisy panels | Braid or foil screen with drain wire |
| Fire resistant control cable | Emergency systems and life safety control | Circuit integrity tested; see the fire resistant cables page |
Pair this page with power cables for load circuits, instrumentation cables for sensor signals, and cable glands and lugs for the terminations.
Work from the circuit schedule: count every signal and spare, add the earth core, then check voltage drop on the longest run. Cores of 1.5 mm2 cover most coil and indicator circuits, and 2.5 mm2 is used where the run to a remote starter is long.
A Prysmian datasheet for a 1.5 mm2 control cable shows the construction most Gulf buyers recognise: PVC insulated cores, white with black numbering and a green and yellow earth core, laid up with PVC bedding, galvanised steel wire armour and a PVC sheath, offered from 2 to 50 cores plus earth at 0.6/1 kV. The datasheet is made to an Australian standard, so a Saudi order should name IEC or BS equivalents instead.
Choose low smoke halogen free (LSHF) sheaths where people sit in enclosed spaces, because PVC gives dense black smoke, toxic fumes and acid gas in a fire. Prysmian says BS 6724 armoured cable replaces PVC sheathed BS 5467 where low smoke, zero halogen performance and reduced flame propagation are required, and notes it is designed to interconnect systems as control or power cable.
Outdoor plant cable in open desert is usually PVC with steel wire armour, because cost matters and smoke affects no occupants. Whichever you pick, state it in the specification. The Saudi Fire Code (SBC 801) and the General Directorate of Civil Defense set where fire resistant circuits are needed, so confirm with the project consultant.
Control cable in Saudi plants faces high ambient and surface temperature, sand abrasion in open trenches and large day-to-night swings. The Prysmian PVC datasheet lists a maximum continuous operating temperature of 75 degrees C, up to 90 degrees C when the cable is not exposed to mechanical deformation, which is exactly the limit reached by cables on sun-heated trays or in bunched roof runs.
As of 2026, Saudi control cable is specified to IEC 60502-1 or BS equivalents, certified under SASO and SABER where in scope, and approved by the owner for plant work. Utility work may add Saudi Electricity Company requirements.
| Requirement | Applies to | Authority or body |
|---|---|---|
| IEC 60502-1 | LV extruded insulation cables | IEC |
| BS 5467, BS 6724, BS 6004 | Armoured and PVC cables named in many specifications | BSI; BASEC approvals |
| IEC 60332 and IEC 61034 tests | Flame propagation and smoke emission | IEC; BASEC descriptions |
| SABER conformity | Regulated electrical products in scope | SASO |
| Owner vendor approval | Aramco, SABIC and utility projects | The owner's procurement and inspection teams |
| Civil Defense and Fire Code | Life safety circuits | General Directorate of Civil Defense |
The SASO and SABER guide explains how a certificate is checked. BASEC's fire test descriptions show what the flame spread and smoke tests actually measure, so you can read a test report against your specification.
Test every core for continuity and insulation resistance after pulling, and record the results against the core schedule. This is standard practice on plant projects and takes far less time than tracing a fault later.
Hand over the core schedule and test sheets with the as-built drawings.
Saudi buyers buy control cable from regional and international manufacturers, direct for projects and through distributors for smaller orders. Makers linked here have documented multicore armoured ranges.
Read the supplier sourcing guide before approving a new cable source on a plant project.
The copper price and the armour weight set most of the cost, and lead time depends on whether the construction is stocked in the Kingdom.
With the core schedule to hand, post your requirement and compare quotes on the same basis.