Laboratory autoclaves in Saudi Arabia are steam sterilisers used by hospital, university, food, petrochemical and pharmaceutical labs to sterilise media, glassware and tools and to decontaminate biological waste. This page sets out the types and what to specify, how Saudi water, heat and distance affect them, where SFDA medical device rules and the SASO pressure equipment regulation apply as of 2026, and how to compare Saudi suppliers.
0 suppliers found
Skip the search. Post your requirement and we'll connect you with verified autoclaves suppliers who quote for your order directly.
Tell us about autoclaves in Saudi Arabia and receive competitive quotes from verified suppliers — free, fast, and no obligation.
Saudi labs buy three broad kinds of autoclave: vertical top-loading units for media and waste, benchtop front-loading units for small loads and instruments, and horizontal or double-door units for high volumes and containment. All of them belong to the laboratory equipment family in Saudi Arabia; this page covers the steriliser in more detail than the family overview, from cycle choice to qualification.
| Autoclave type | Where Saudi labs use it | Specification points |
|---|---|---|
| Vertical (top-loading) | Culture media and glassware in university, food and water microbiology labs in Riyadh, Jeddah and Dammam | Usable volume, number of baskets, liquids cycle with load temperature probe, automatic lid lock until the load has cooled |
| Benchtop (front-loading) | Small QC rooms, clinic labs, sterilising tools and small instruments | EN 13060 class if used on medical devices, water reservoir, drying, cycle printout or data export |
| Horizontal (floor-standing) | Hospital microbiology, pharmaceutical QC in industrial cities, large waste volumes | Chamber to suit carts and racks, vacuum and drying, steam from an integrated generator or the plant, three-phase power |
| Double-door (pass-through) | Biosafety containment suites and GMP clean areas | Interlocked doors, bioseal or wall flange, loading and unloading sides, service access |
| Waste decontamination unit | Lab waste made safe before collection by a licensed contractor | Validated waste cycle, exhaust treatment, bag and bin compatibility, daily throughput |
EN 13060 and EN 285 are the two European steriliser standards Saudi tenders quote. EN 13060 is for chambers under 60 litres that cannot take a 300 x 300 x 600 mm module, and was replaced by a 2025 edition from 1 September 2025; EN 285 covers 60 litres and above. Under EN 13060, W&H explains, Type B suits porous, hollow and wrapped loads, Type N only bare solid items, and Type S whatever loads the maker specifies. Neither standard is written for lab media or waste: EN 13060 excludes sterilisers for liquids, and EN 285 excludes biological waste. A media or waste autoclave is therefore accepted on the maker's validated cycles and on your own testing.
Hospital sterile services departments buy separately under sterilization equipment for Saudi hospitals, and labs without on-site treatment hand waste to medical waste treatment contractors. Media bottles, tubes and bags must be autoclavable, so check them against supplier data under lab consumables and reagents in Saudi Arabia; molecular labs also autoclave tips and tubes for their PCR and molecular biology equipment.
Feed water, room heat and the distance to the nearest service engineer are the Saudi factors that most affect an autoclave's uptime. Water quality varies by city and source, so specify treatment rather than assume it.
As of 2026, a steriliser intended for sterilising medical devices is a class B medical device under SFDA rules and needs an SFDA Medical Device Marketing Authorization (MDMA), while other pressure equipment may fall under the SASO Technical Regulation for Pressure Equipment. A lab autoclave used only for media and waste is not a medical device, so check which route applies to the model and its stated use.
| Requirement | Applies to | Authority |
|---|---|---|
| MDMA; rule 16 of MDS-REQ 1 classes devices for sterilising medical devices as class B | Sterilisers sold for reprocessing medical devices | Saudi Food and Drug Authority (SFDA) |
| Technical Regulation for Pressure Equipment (approved October 2022, published December 2022) | Pressure equipment with maximum allowable pressure above 0.5 bar, with listed exclusions | SASO, certificates through SABER |
| EN 13060:2025 and EN 285:2015+A1:2021 | Small and large steam sterilisers for medical devices | CEN |
| ISO 17665:2024 | Development, validation and routine control of moist heat sterilisation | ISO |
| ISO/IEC 17025 and ISO 15189 | Testing and medical labs relying on sterile media and records | Saudi Accreditation Center (SAAC) |
The SASO regulation applies to pressure equipment above 0.5 bar but excludes category I and lower equipment that is covered by certain other regulations, including medical products under SFDA requirements and the low voltage electrical equipment regulation. Whether a given autoclave needs a pressure equipment certificate therefore depends on its pressure category and use, so ask the supplier which SABER certificate it holds for the model. The SASO and SABER certificates guide explains how product and shipment certificates work.
For routine control, CDC's January 2026 guidance for waste autoclaves recommends biological indicators with spores such as Geobacillus stearothermophilus on each new indicator batch, at least monthly and after any repair, with waste held and the unit stopped if a retest is also positive. Ask the supplier for qualification with temperature mapping on handover, verified with temperature calibrators that trace to an accredited laboratory.
Saudi labs buy autoclaves from scientific distributors in Riyadh, Jeddah and Dammam that carry several makers, while government hospital labs often buy through NUPCO tenders. Judge each bid on the local service team as much as on the machine.
Makers carried here include RAYPA (vertical top-loading and front-loading benchtop laboratory autoclaves), BIOBASE (Class N and Class B benchtop units plus vertical, horizontal and portable autoclaves) and Infitek (autoclaves and sterilisers within a wider lab range). Questions to put to each Saudi supplier:
The sourcing guide for Saudi and UAE suppliers covers vendor due diligence, and you can post your requirement to collect offers from Saudi suppliers against one specification.
Price rises with chamber size, door layout, vacuum and drying, the steam source and the documentation package. GMP labs pay more for cycle software with an audit trail and for full qualification; pass-through units need wall works and sealing.
Benchtop and vertical units are often stocked by Saudi distributors. Horizontal and double-door units are made to order, shipped through Jeddah Islamic Port or King Abdulaziz Port in Dammam, and then wait for power, drains and water to be ready on site. Regulatory steps come first: a model needing an MDMA or a SABER certificate cannot be cleared or supplied until it has one.